Logotipo do repositório
 

Publicação:
Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

dc.contributor.authorOliveira, Matheus Lima de
dc.contributor.authorTosoni, Guilherme Monteiro [UNESP]
dc.contributor.authorLindsey, David H.
dc.contributor.authorMendoza, Kristopher Anthony
dc.contributor.authorTetradis, Sotirios
dc.contributor.authorMallya, Sanjay M.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversity of California
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.date.accessioned2015-08-06T16:12:41Z
dc.date.available2015-08-06T16:12:41Z
dc.date.issued2014
dc.description.abstractTo assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods Tubes containing solutions with different concentrations of K2HPO4 were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the K2HPO4 solutions were measured. The relationship between CT number and K2HPO4 concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results The relationship between K2HPO4 concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.en
dc.description.affiliationSection of Oral and Maxillofacial Radiology
dc.description.affiliationDepartment of Oral Diagnosis
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Diagnóstico e Cirurgia, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680, Centro, CEP 14801903, SP, Brasil
dc.format.extent279-285
dc.identifierhttp://synapse.koreamed.org/DOIx.php?id=10.5624/isd.2014.44.4.279
dc.identifier.citationImaging Science in Dentistry, v. 44, n. 4, p. 279-285, 2014.
dc.identifier.doi10.5624/isd.2014.44.4.279
dc.identifier.issn2233-7822
dc.identifier.lattes3156969817236677
dc.identifier.lattes0692567697594977
dc.identifier.urihttp://hdl.handle.net/11449/125640
dc.language.isoeng
dc.relation.ispartofImaging Science in Dentistry
dc.relation.ispartofsjr0,572
dc.rights.accessRightsAcesso restritopt
dc.sourceCurrículo Lattes
dc.subjectCone-Beam Computed Tomographyen
dc.subjectImage Processingen
dc.subjectComputer-Assisteden
dc.subjectImagingen
dc.subjectThree-Dimensionalen
dc.titleAssessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scannersen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes3156969817236677
unesp.author.lattes0692567697594977
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos