Photoelastic Analysis of Cemented or Screwed Implant-Supported Prostheses With Different Prostheses Connections

dc.contributor.authorTonella, Bianca Piccolotto [UNESP]
dc.contributor.authorPellizzer, Eduardo Piza [UNESP]
dc.contributor.authorFerraco, Renato [UNESP]
dc.contributor.authorFalcon-Antenucci, Rosse Mary [UNESP]
dc.contributor.authorPerri de Carvalho, Paulo S.
dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:29:42Z
dc.date.accessioned2014-05-20T13:43:24Z
dc.date.available2013-09-30T18:29:42Z
dc.date.available2014-05-20T13:43:24Z
dc.date.issued2011-08-01
dc.description.abstractThe aim of this study was to evaluate the stress distribution of different retention systems (screwed or cemented) associated with different prosthetic connections (external hexagon, internal hexagon, and Morse taper) in 3-unit implant-supported fixed partial dentures through photoelasticity. Six models were fabricated with photoelastic resin PL-2, and each model contained two implants of 4.0 x 10.0 mm. The models presented different retention systems (screwed and cemented) and different connections (external hexagon, internal hexagon, and Morse taper). The prostheses were standardized and fabricated in Ni-Cr alloy. A circular polariscope was used and axial and oblique (45) loads of 100 N were applied in a universal testing machine. The results were photographed and analyzed qualitatively with a graphic software (Adobe Photoshop). The screwed retention system exhibited higher number of fringes for both axial and oblique loadings. The internal hexagon implant presented better and lower stress distribution for both cemented and screwed prostheses. The oblique loading increased the number of fringes in all models tested. The cemented retention system presented better stress distribution. The internal hexagon implant was more favorable according to the biomechanical standpoint. The oblique load increased stress in all systems and connections tested.en
dc.description.affiliationSão Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationSão Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Surg, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Surg, São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 07/55061-3
dc.format.extent401-410
dc.identifierhttp://dx.doi.org/10.1563/AAID-JOI-D-10-00044
dc.identifier.citationJournal of Oral Implantology. Lawrence: Allen Press Inc, v. 37, n. 4, p. 401-410, 2011.
dc.identifier.doi10.1563/AAID-JOI-D-10-00044
dc.identifier.issn0160-6972
dc.identifier.lattes5581364193525500
dc.identifier.lattes9719883814872582
dc.identifier.orcid0000-0002-3800-3050
dc.identifier.urihttp://hdl.handle.net/11449/15136
dc.identifier.wosWOS:000294311700004
dc.language.isoeng
dc.publisherAllen Press Inc
dc.relation.ispartofJournal of Oral Implantology
dc.relation.ispartofjcr1.212
dc.relation.ispartofsjr0,569
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectdental implantsen
dc.subjectfixed partial dentureen
dc.subjectimplant-supported fixed partial dentureen
dc.titlePhotoelastic Analysis of Cemented or Screwed Implant-Supported Prostheses With Different Prostheses Connectionsen
dc.typeArtigopt
dcterms.licensehttp://www.joionline.org/userimages/ContentEditor/1240858717108/Terms_and_Conditions_ORIM1.pdf
dcterms.rightsHolderAllen Press Inc
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes5581364193525500
unesp.author.lattes9719883814872582
unesp.author.orcid0000-0002-3800-3050[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: