Logotipo do repositório
 

Publicação:
Effects of laser-weld joint opening size on fatigue strength of Ti-6Al-4V structures with several diameters

dc.contributor.authorNunez-Pantoja, J. M. C.
dc.contributor.authorVaz, Luis Geraldo [UNESP]
dc.contributor.authorNobilo, M. A. A.
dc.contributor.authorHenriques, G. E. P.
dc.contributor.authorMesquita, M. F.
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:46:31Z
dc.date.available2014-05-20T13:46:31Z
dc.date.issued2011-03-01
dc.description.abstractP>This study was conducted to evaluate the fatigue strength of Ti-6Al-4V laser-welded joints with several diameters and joint openings. Sixty dumbbell rods were machined in Ti-6Al-4V alloy with central diameters of 1 center dot 5, 2 center dot 0 and 3 center dot 5 mm. The specimens were sectioned and then welded using two joint openings (0 center dot 0 and 0 center dot 6 mm). The combination of variables created six groups, which when added to the intact groups made a total of nine groups (n = 10). Laser welding was executed as follows: 360 V per 8 ms (1 center dot 5 and 2 center dot 0 mm) and 380 V per 9 ms (3 center dot 5 mm) with focus and frequency regulated to zero. The joints were finished, polished and submitted to radiographic examination to be analysed visually for the presence of porosity. The specimens were then subjected to a mechanical cyclic test, and the number of cycles until failure was recorded. The fracture surface was examined with a scanning electron microscope (SEM). The Kruskal-Wallis test and Dunn test (alpha = 0 center dot 05) indicated that the number of cycles required for fracture was lower for all specimens with joint openings of 0 center dot 6 mm, and for 3 center dot 5-mm-diameter specimens with joint openings of 0 center dot 0 mm. The Spearman correlation coefficient (alpha = 0 center dot 05) indicated that there was a negative correlation between the number of cycles and the presence of porosity. So, laser welding of Ti-6Al-4V structures with a thin diameter provides the best conditions for the juxtaposition of parts. Radiographic examination allows for the detection of internal voids in titanium joints.en
dc.description.affiliationUniv Estadual Campinas, Dept Prosthodont & Periodontol, Piracicaba Dent Sch, Piracicaba, SP, Brazil
dc.description.affiliationState Univ São Paulo Julio de Mesquita Filho, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationUnespState Univ São Paulo Julio de Mesquita Filho, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipNEODENT Industria e Comercio de Materiais Dentarios - Ltda.
dc.description.sponsorshipIdFAPESP: 06/58816-2
dc.description.sponsorshipIdFAPESP: 07/51306-1
dc.format.extent196-201
dc.identifierhttp://dx.doi.org/10.1111/j.1365-2842.2010.02140.x
dc.identifier.citationJournal of Oral Rehabilitation. Malden: Wiley-blackwell Publishing, Inc, v. 38, n. 3, p. 196-201, 2011.
dc.identifier.doi10.1111/j.1365-2842.2010.02140.x
dc.identifier.issn0305-182X
dc.identifier.lattes8547747556446020
dc.identifier.urihttp://hdl.handle.net/11449/16472
dc.identifier.wosWOS:000287037400006
dc.language.isoeng
dc.publisherWiley-Blackwell Publishing, Inc
dc.relation.ispartofJournal of Oral Rehabilitation
dc.relation.ispartofjcr2.051
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjecttitanium structuresen
dc.subjecttitanium alloysen
dc.subjectfatigue performanceen
dc.subjectlaser-weld jointen
dc.subjectdental implant prosthesesen
dc.titleEffects of laser-weld joint opening size on fatigue strength of Ti-6Al-4V structures with several diametersen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell Publishing, Inc
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes8547747556446020
unesp.author.orcid0000-0003-0916-1962[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: