Logotipo do repositório
 

Publicação:
Perfusão cerebral e análise individual automatizada utilizando SPECT em uma população com transtorno obsessivo-compulsivo

dc.contributor.authorda Rocha, Euclides Timóteo [UNESP]
dc.contributor.authorBuchpiguel, Carlos Alberto
dc.contributor.authorMiguel, Euripedes Constantino
dc.contributor.authorPeres, Stela Verzinhase
dc.contributor.authorFilho, Geraldo Busatto
dc.contributor.institutionHospital de Câncer - Fundação Pio XII
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionNuclear Medicine Service
dc.date.accessioned2014-05-27T11:25:51Z
dc.date.available2014-05-27T11:25:51Z
dc.date.issued2011-04-26
dc.description.abstractObjective: To make individual assessments using automated quantification methodology in order to screen for perfusion abnormalities in cerebral SPECT examinations among a sample of subjects with OCD. Methods: Statistical parametric mapping (SPM) was used to compare 26 brain SPECT images from patients with OCD individually with an image bank of 32 normal subjects, using the statistical threshold of p < 0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). The maps were analyzed, and regions presenting voxels that remained above this threshold were sought. results: Six patients from a sample of 26 OCD images showed abnormalities at cluster or voxel level, considering the criteria described above, which represented 23.07%. However, seven images from the normal group of 32 were also indicated as cases of perfusional abnormality, representing 21.8% of the sample. Conclusion: The automated quantification method was not considered to be a useful tool for clinical practice, for analyses complementary to visual inspection.en
dc.description.affiliationHospital de Câncer - Fundação Pio XII Department of Nuclear Medicine, Barretos, SP
dc.description.affiliationSão Paulo State University (Unesp) Medical School Blood Transfusion Center, Botucatu, SP
dc.description.affiliationUniversity of São Paulo (USP) School of Medicine Department of Radiology, Nuclear Medicine Service
dc.description.affiliationUSP School of Medicine Institute of Psychiatry
dc.description.affiliationHospital de Câncer - Fundação Pio XII
dc.description.affiliationDepartment of Radiology Nuclear Medicine Service
dc.description.affiliationUnespSão Paulo State University (Unesp) Medical School Blood Transfusion Center, Botucatu, SP
dc.format.extent1-6
dc.identifierhttp://dx.doi.org/10.1590/S0047-20852011000100001
dc.identifier.citationJornal Brasileiro de Psiquiatria, v. 60, n. 1, p. 1-6, 2011.
dc.identifier.doi10.1590/S0047-20852011000100001
dc.identifier.file2-s2.0-79955047693.pdf
dc.identifier.issn0047-2085
dc.identifier.issn1982-0208
dc.identifier.scieloS0047-20852011000100001
dc.identifier.scopus2-s2.0-79955047693
dc.identifier.urihttp://hdl.handle.net/11449/72391
dc.language.isopor
dc.relation.ispartofJornal Brasileiro de Psiquiatria
dc.relation.ispartofsjr0,224
dc.rights.accessRightsAcesso abertopt
dc.sourceScopus
dc.subjectBrain SPECT
dc.subjectIndividual analysis
dc.subjectOCD
dc.subjectSPM
dc.subjectcysteine ethyl ester tc 99m
dc.subjectadult
dc.subjectautomation
dc.subjectbrain mapping
dc.subjectbrain perfusion
dc.subjectclinical article
dc.subjectclinical assessment
dc.subjectcontrolled study
dc.subjectfemale
dc.subjecthuman
dc.subjectimage processing
dc.subjectmale
dc.subjectobsessive compulsive disorder
dc.subjectprediction
dc.subjectsingle photon emission computer tomography
dc.titlePerfusão cerebral e análise individual automatizada utilizando SPECT em uma população com transtorno obsessivo-compulsivopt
dc.title.alternativeCerebral perfusion and automated individual analysis using spect among an obsessive-compulsive populationen
dc.typeArtigopt
dcterms.licensehttp://www.scielo.br/revistas/jbpsiq/paboutj.htm
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-79955047693.pdf
Tamanho:
678.85 KB
Formato:
Adobe Portable Document Format