Assessing the cyclic fatigue resistance and sterilization effects on replica-like endodontic instruments compared to Reciproc Blue

dc.contributor.authordos Reis, Fernando Antonio Siano
dc.contributor.authorAbu Hasna, Amjad [UNESP]
dc.contributor.authorRagozzini, Gustavo
dc.contributor.authorde Moura, Felipe Bernardo [UNESP]
dc.contributor.authorCampos, Tiago Moreira Bastos
dc.contributor.authorde Martin, Alexandre Sigrist
dc.contributor.authorCarvalho, Cláudio Antonio Talge [UNESP]
dc.contributor.authorBueno, Carlos Eduardo Silveira
dc.contributor.institutionEndodontia
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniversidad Espíritu Santo
dc.contributor.institutionAeronautics Technological Institute (ITA)
dc.date.accessioned2025-04-29T18:48:42Z
dc.date.issued2023-12-01
dc.description.abstractThis study aimed to evaluate the effect of the number of uses and autoclave sterilization on the cyclic fatigue resistance of four replica-like instruments RC Blue; Only One File Blue; Recip One Blue; and Micro Blue compared to the original system Reciproc Blue (VDW, Munich, Germany). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). Fifty molars were instrumented by ten instruments (n=10). After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more using different molars, totaling 3 rounds of instrumentation, sterilization and SEM analysis. Then, ten different instruments from each brand were tested for cyclic fatigue resistance. Number of uses data were analyzed using Chi-squared analysis, and cyclic fatigue data were analyzed by one-way Anova followed by Tukey’s test as the data had normal distribution. The fracture times for all systems had no significant difference, but Micro Blue had significantly lower values than the other systems (p < 0.05). The SEM analysis showed distortions in the instruments after the 3rd use. Therefore, all tested instruments except of Micro Blue have similar resistance to cyclic fatigue, and all are reliable for use in up to 2-cases.en
dc.description.affiliationFaculdade São Leopoldo Mandic Instituto de Pesquisas São Leopoldo Mandic Endodontia, SP
dc.description.affiliationDepartment of Restorative Dentistry Endodontics Division Institute of Science and Technology São Paulo State University (UNESP), Av. Eng. Francisco José Longo Avenue 777, SP
dc.description.affiliationSchool of Dentistry Universidad Espíritu Santo
dc.description.affiliationPhysics Department Aeronautics Technological Institute (ITA), SP
dc.description.affiliationUnespDepartment of Restorative Dentistry Endodontics Division Institute of Science and Technology São Paulo State University (UNESP), Av. Eng. Francisco José Longo Avenue 777, SP
dc.identifierhttp://dx.doi.org/10.1038/s41598-023-50096-2
dc.identifier.citationScientific Reports, v. 13, n. 1, 2023.
dc.identifier.doi10.1038/s41598-023-50096-2
dc.identifier.issn2045-2322
dc.identifier.scopus2-s2.0-85180710992
dc.identifier.urihttps://hdl.handle.net/11449/300139
dc.language.isoeng
dc.relation.ispartofScientific Reports
dc.sourceScopus
dc.titleAssessing the cyclic fatigue resistance and sterilization effects on replica-like endodontic instruments compared to Reciproc Blueen
dc.typeArtigopt
dspace.entity.typePublication
unesp.author.orcid0009-0008-3135-3067[1]
unesp.author.orcid0000-0002-1112-985X[2]
unesp.author.orcid0009-0007-4012-2829[3]
unesp.author.orcid0000-0002-3320-9172[6]
unesp.author.orcid0000-0003-0987-5594[7]
unesp.author.orcid0000-0002-2675-0884[8]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt

Arquivos