Logotipo do repositório
 

Publicação:
Avaliações ultra-sonográfica, macroscópica e histológica da biopsia testicular em ovinos

dc.contributor.authorSartori, R.
dc.contributor.authorPrestes, N.C. [UNESP]
dc.contributor.authorCanavessi, A.M.O.
dc.contributor.authorKempinas, W.G. [UNESP]
dc.contributor.authorRosa, G.J.M. [UNESP]
dc.contributor.institutionUniversity of Wisconsin Dairy Science Department
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversity of Wisconsin
dc.date.accessioned2014-05-20T15:12:50Z
dc.date.available2014-05-20T15:12:50Z
dc.date.issued2002-06-01
dc.description.abstractDevido ao fato da biopsia testicular poder acarretar hemorragia, inflamação, degeneração, aderência e fibrose, especialmente com as técnicas incisionais ou abertas, este trabalho avaliou a aplicabilidade de uma técnica menos invasiva (biopsia com agulha Tru-Cut) em ovinos na obtenção de material para histologia e acompanhou as lesões testiculares posteriores. Trinta carneiros foram igualmente divididos em três grupos: 1) controle, animais não submetidos à biopsia; 2) submetidos à biopsia + cola de fibrina nos locais da biopsia testicular e incisões da pele; e 3) submetidos à biopsia + sutura da pele escrotal após a biopsia. Exames ultra-sonográficos foram realizados pré e pós biopsia. No centésimodia, os testículos foram avaliados macro e microscopicamente após orquiectomia. A ultra-sonografia permitiu mapear as alterações ocorridas e acompanhar a evolução das seqüelas. Ao exame macroscópico, pequenas áreas de calcificação foram observadas em 55 e 70% dos testículos nos grupos 2 e 3, respectivamente. A biopsia com agulha Tru-Cut forneceu material suficiente para histologia mas ocasionou lesões focais restritas à área biopsiada. Apesar da possível ocorrência de calcificação e outras lesões mínimas, foi demonstrado que a biopsia com agulha Tru-Cut em ovinos é um procedimento seguro por não ter comprometido significativamente as características estruturais e funcionais dos testículos.pt
dc.description.abstractBecause testicular biopsy can cause hemorrhage, inflammation, degeneration, adhesion, and fibrosis, especially if using the incisional or open biopsy techniques, the present study evaluated if testicular biopsy with Tru-Cut needle (a less invasive technique) in rams provides enough material for histology, and followed the subsequent testicular lesions. Thirty rams were evenly assigned to three groups: 1) control, no biopsy; 2) biopsy + fibrin glue on biopsy sites and skin incisions; and 3) biopsy + scrotal skin suture after biopsy. Ultrasonographic examinations were performed before and after biopsy. Orchiectomy was carried out on day 100 and the testicles were examined for gross and microscopic lesions. Ultrasonography permitted to map testicular alterations and to follow the evolution of the lesions. Small areas of calcification were observed in 55 and 70% of testicles from groups 2 and 3, respectively. Testicular biopsy with Tru-Cut needle provided enough material for histology but induced small and focal areas of testicular lesions close to the biopsy site. In spite of the potential occurrence of calcification and other minimal lesions, it was shown that testicular biopsy with Tru-Cut needle in rams is safe because did not significantly compromise the functional and structural testicular characteristics.en
dc.description.affiliationUniversity of Wisconsin Dairy Science Department
dc.description.affiliationUNESP Faculdade de Medicina Veterinária e Zootecnia
dc.description.affiliationUniversity of Wisconsin
dc.description.affiliationUNESP Instituto de Biociências
dc.description.affiliationUnespUNESP Faculdade de Medicina Veterinária e Zootecnia
dc.description.affiliationUnespUNESP Instituto de Biociências
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extent233-241
dc.identifierhttp://dx.doi.org/10.1590/S0102-09352002000300003
dc.identifier.citationArquivo Brasileiro de Medicina Veterinária e Zootecnia. Universidade Federal de Minas Gerais, Escola de Veterinária, v. 54, n. 3, p. 233-241, 2002.
dc.identifier.doi10.1590/S0102-09352002000300003
dc.identifier.issn0102-0935
dc.identifier.lattes6326450271169741
dc.identifier.scieloS0102-09352002000300003
dc.identifier.urihttp://hdl.handle.net/11449/28531
dc.language.isopor
dc.publisherUniversidade Federal de Minas Gerais (UFMG), Escola de Veterinária
dc.relation.ispartofArquivo Brasileiro de Medicina Veterinária e Zootecnia
dc.relation.ispartofjcr0.286
dc.relation.ispartofsjr0,248
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectBiopsiapt
dc.subjecttestículopt
dc.subjectovinopt
dc.subjectultra-sonografiapt
dc.subjecthistopatologiapt
dc.subjectBiopsyen
dc.subjecttesticleen
dc.subjectsheepen
dc.subjectultrasonographyen
dc.subjecthistopathologyen
dc.titleAvaliações ultra-sonográfica, macroscópica e histológica da biopsia testicular em ovinospt
dc.title.alternativeAssessment of ultrasonographic images and gross and microscopic lesions of the testicular biopsy in sheepen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes6326450271169741
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Biociências, Botucatupt
unesp.departmentMorfologia - IBBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: