Logo do repositório
 

The Effect of Mechanical Cycling and Different Misfit Levels on Vicker's Microhardness of Retention Screws for Single Implant-Supported Prostheses

dc.contributor.authorAssunção, Wirley Goncalves [UNESP]
dc.contributor.authorPala Jorge, Juliana Ribeiro [UNESP]
dc.contributor.authorSantos, Paulo Henrique dos [UNESP]
dc.contributor.authorBarao, Valentim Adelino Ricardo [UNESP]
dc.contributor.authorGomes, Erica Alves [UNESP]
dc.contributor.authorDelben, Juliana Aparecida [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:12Z
dc.date.accessioned2014-05-20T13:43:47Z
dc.date.available2013-09-30T18:30:12Z
dc.date.available2014-05-20T13:43:47Z
dc.date.issued2011-10-01
dc.description.abstractPurpose: The aim of this study was to evaluate the effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant-supported prostheses.Materials and Methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n = 12). The crowns presented no misfit in group A (control group) and unilateral misfits of 50 mu m, 100 mu m, and 200 mu m in groups B, C, and D, respectively. The crowns were screwed to external hexagon implants with titanium retention screws (torque of 30 N/cm), and the sets were submitted to three different periods of mechanical cycling: 2 x 10(4), 5 x 10(4), and 1 x 10(6) cycles. Screw microhardness values were measured before and after each cycling period. Data were evaluated by two-way ANOVA and Tukey's test (p < 0.05).Results: Mechanical cycling statistically reduced microhardness values of retention screws regardless of cycling periods and groups. In groups A, B, and C, initial microhardness values were statistically different from final microhardness values (p < 0.05). There was no statistically significant difference for initial screw microhardness values (p > 0.05) among the groups; however, when the groups were compared after mechanical cycling, a statistically significant difference was observed between groups B and D (p < 0.05).Conclusions: Mechanical cycling reduced the Vicker's microhardness values of the retention screws of all groups. The crowns with the highest misfit level presented the highest Vicker's microhardness values.en
dc.description.affiliationUniv Estadual Paulista UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.format.extent523-527
dc.identifierhttp://dx.doi.org/10.1111/j.1532-849X.2011.00753.x
dc.identifier.citationJournal of Prosthodontics-implant Esthetic and Reconstructive Dentistry. Malden: Wiley-blackwell, v. 20, n. 7, p. 523-527, 2011.
dc.identifier.doi10.1111/j.1532-849X.2011.00753.x
dc.identifier.issn1059-941X
dc.identifier.lattes4438747643373395
dc.identifier.lattes0493479801083622
dc.identifier.orcid0000-0002-4100-5153
dc.identifier.urihttp://hdl.handle.net/11449/15304
dc.identifier.wosWOS:000296841000005
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofJournal of Prosthodontics-implant Esthetic and Reconstructive Dentistry
dc.relation.ispartofjcr1.745
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectMechanical cyclingen
dc.subjectretention-screw microhardnessen
dc.subjectimplant-supported prosthesesen
dc.subjectmisfiten
dc.titleThe Effect of Mechanical Cycling and Different Misfit Levels on Vicker's Microhardness of Retention Screws for Single Implant-Supported Prosthesesen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-blackwell
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes4438747643373395
unesp.author.lattes0493479801083622[3]
unesp.author.orcid0000-0002-8903-0737[1]
unesp.author.orcid0000-0002-6391-9917[4]
unesp.author.orcid0000-0002-6510-3727[6]
unesp.author.orcid0000-0002-4100-5153[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: