Logo do repositório
 

Standardization of an experimental model of parabiotic isolated heart in rabbits

dc.contributor.authorMartins, Antonio Sérgio [UNESP]
dc.contributor.authorSilva, Marcos Augusto de Moraes [UNESP]
dc.contributor.authorMatsubara, Beatriz Bojikian [UNESP]
dc.contributor.authorAragon, Flávio Ferrari [UNESP]
dc.contributor.authorPadovani, Carlos Roberto [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:33:01Z
dc.date.available2014-05-20T13:33:01Z
dc.date.issued2000-09-01
dc.description.abstractO objetivo foi a padronização de modelo experimental de coração isolado parabiótico em coelhos, testando sua estabilidade e durabilidade, para fins de pesquisa cardiovascular. Foram utilizados 66 coelhos raça Norfolk-2000 divididos em grupo doador do coração isolado e animais suporte, totalizando 33 preparações. Mediante auxilio de bombas peristálticas estabeleceu-se suporte circulatório para o coração isolado mantendo-se fluxo constante(16ml/min.). Um balão intraventricular foi inserido no ventrículo esquerdo, sendo ajustado para gerar pressão diastólica de ± 10mmHg. A freqüência foi fixada em 120 batimentos por minuto mediante o uso de marcapasso. Foram avaliadas variáveis hemodinâmicas, laboratoriais e anatomopatológicas. Das 33 preparações, 13 foram excluídas mediante critérios pré-estabelecidos. Das 20 restantes, 10 cumpriram o tempo máximo do protocolo(180 minutos). Com relação ao animal suporte houve deterioração hemodinâmica progressiva c/ queda da pressão arterial média(89,30±6,09mmHg->47,50±6,35mmHg). Com relação ao corações isolado, das 10 preparações que cumpriram os 180 minutos de protocolo, houve estabilidade hemodinâmica. As variáveis laboratoriais mostraram queda progressiva do sódio, potássio e hemoglobina, sendo compatível com hemodiluição. O exame anatomopatológico mostrou espaçamento maior entre fibras, compatível com edema. O presente modelo mostrou estabilidade e atividade de 100% das preparações em 60 minutos, havendo perdas progressivas chegando a 50% das preparações em atividade em 180 minutos. O presente modelo, dentro das limitações estabelecidas é viável para pesquisas cardiovasculares.pt
dc.description.abstractThe objective was to standardize an experimental model of parabiotic isolated heart in rabbits, testing their stability and durability for use in cardiovascular research. Sixty-six Norfolk-2000 rabbits were used and divided in 2 groups: donors of the isolated heart and support animals, in a total of 33 preparations. Circulatory support for the isolated heart was established with the aid of peristaltic pumps and the flow was kept constant (16ml/min.). An intraventricular balloon was inserted in the left ventriculum, and was adjusted to produce diastolic pressure of ± 10mmHg. Heart rate was established at 120 beats per minute with the use of a pacemaker. Hemodynamic, laboratory and histopathological parameters were evaluated. of the 33 preparations, 13 were excluded according to preestablished criteria. of the 20 remaining preparations, 10 completed the maximum protocol time (180 minutes). There was progressive hemodynamic deterioration with decrease of mean blood pressure (89.30±6.09mmHg->47.50±6.35mmHg) in the support animal. There was hemodynamic stability of the isolated heart for the 10 preparations that completed the 180 minutes of the protocol. Laboratory parameters showed progressive decrease of sodium, potassium and hemoglobin, which is compatible with hemodilution. Histopathology showed greater distance among the fibers, compatible with edema. The present model showed 100% stability and activity of the preparations within 60 minutes, and 50% of the active preparations were progressively lost within 180 minutes. The present model is viable for cardiovascular research.en
dc.description.affiliationUniversidade Estadual de São Paulo FMB Department of Surgery
dc.description.affiliationUniversidade Estadual de São Paulo FMB Department of Cardiology
dc.description.affiliationUniversidade Estadual de São Paulo IB Department of Statistics
dc.identifierhttp://dx.doi.org/10.1590/S0102-86502000000300004
dc.identifier.citationActa Cirúrgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 15, n. 3, p. 00-00, 2000.
dc.identifier.doi10.1590/S0102-86502000000300004
dc.identifier.issn0102-8650
dc.identifier.lattes6990977122340795
dc.identifier.lattes8727897080522289
dc.identifier.lattes9919910234219937
dc.identifier.scieloS0102-86502000000300004
dc.identifier.urihttp://hdl.handle.net/11449/11289
dc.language.isoeng
dc.publisherSociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.relation.ispartofActa Cirúrgica Brasileira
dc.relation.ispartofjcr0.933
dc.relation.ispartofsjr0,395
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectCoraçãopt
dc.subjectModelos cirúrgicospt
dc.subjectFunção ventricularpt
dc.subjectHearten
dc.subjectCastsen
dc.subjectVentricular functionen
dc.titleStandardization of an experimental model of parabiotic isolated heart in rabbitsen
dc.title.alternativePadronização de modelo experimental de coração isolado parabiótico em coelhospt
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes6990977122340795
unesp.author.lattes8727897080522289[5]
unesp.author.lattes9919910234219937
unesp.author.orcid0000-0002-7719-9682[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Biociências, Botucatupt
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentCirurgia e Ortopedia - FMBpt
unesp.departmentClínica Médica - FMBpt
unesp.departmentBioestatística - IBBpt

Arquivos

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: