Logotipo do repositório
 

Publicação:
Avaliação da confiabilidade e modo de falha de coroas cerâmicas parafusadas a implantes osseointegráveis de diferentes conexões

dc.contributor.advisorAssunção, Wirley Goncalves [UNESP]
dc.contributor.authorDelben, Juliana Aparecida [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-06-11T19:35:03Z
dc.date.available2014-06-11T19:35:03Z
dc.date.issued2012-10-25
dc.description.abstractIntrodução: A performance de restaurações cerâmicas parafusadas a implantes com diferentes conexões diante de fadiga é um fator importante para o sucesso do tratamento. Proposição: O objetivo do estudo foi avaliar a confiabilidade e o modo de falha de coroas cerâmicas obtidas com pilares de zircônia parafusadas a implantes osseointegráveis de diferentes conexões. Material e método: Foram formados 3 grupos de acordo com as diferentes conexões pilar-implante: Grupo EH - hexágono externo, Grupo IH - hexágono interno e Grupo MT - Cone Morse. As coroas foram obtidas através da aplicação de cerâmica de revestimento sobre pilar de zircônia utilizando a técnica de aplicação em camadas e parafusadas aos implantes com parafusos de retenção específicos para cada sistema. Os espécimes foram submetidos ao teste de fadiga acelerado step-stress de acordo com os perfis leve (n=9), moderado (n=6) e agressivo (n=3) determinados após teste de resistência à fratura (n=4) em máquina de ensaio universal. Os dados foram inicialmente avaliados pela análise de use level probability Weibull. Os valores e intervalos de confiabilidade foram obtidos através de standard probability calculation. Considerando os valores de carga para a falha dos espécimes, foi calculada a distribuição de Weibull. Análise fractográfica foi conduzida através de estereomicroscopia e microscopia eletrônica de varredura. Resultado: O valor de β de todos os grupos (EH-β= 0,6307; IH-β=0,9730; MT-β=0,1942) sugere que as falhas foram mais associadas ao nível de carga do que ao dano acumulado. Os valores de confiabilidade para uma missão de 50.000 ciclos e carga de 400 N foram de 97% para o grupo EH, 46% para o grupo IH e 0,5% para o grupo MT com...pt
dc.description.abstractIntroduction: The performance of screw-retained all-ceramic crowns attached to implants with different connections under fatigue is a relevant factor for treatment success. Purpose: The aim of this study was to evaluate the reliability and failure mode of screw-retained all-ceramic crowns fabricated with zirconia abutments attached to osseointegrated implants with different connections. Material and method: Three groups were designed according to the implant-abutment connection: Group EH - external hexagon, Group IH - internal hexagon and Group MT - Morse taper. Layering technique was used for veneering of zirconia abutments. The crowns were attached to the implants with the retention screws of each system. Step-stress accelerated fatigue test was conducted according to mild (n=9), moderate (n=6) and aggressive (n=3) profiles determined after single-load-to-fracture test (n=4) in a universal testing machine. Data was previously analyzed by use level probability Weibull. Standard probability calculation was used to determine the reliability and confidence bounds. Weibull distribution was calculated based on the load to failure. Failure modes were described under light polarized microscopy and scanning electron microscopy. Result: β of all groups (EH-β= 0.6307; IH-β=0.9730; MT-β=0.1942) suggested that failure was associated to load instead of cumulative damage. Significant difference was observed between the groups for the calculated reliability in a mission of 50,000 cycles at 400 N (97% for group EH, 46% for group IH... (Complete abstract click electronic access below)en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.format.extent164 f. : il. + 1 CD-ROM
dc.identifier.aleph000716909
dc.identifier.capes33004021011P0
dc.identifier.citationDELBEN, Juliana Aparecida. Avaliação da confiabilidade e modo de falha de coroas cerâmicas parafusadas a implantes osseointegráveis de diferentes conexões. 2012. 164 f. Tese (doutorado) - Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araçatuba, 2012.
dc.identifier.filedelben_ja_dr_araca.pdf
dc.identifier.lattes4438747643373395
dc.identifier.urihttp://hdl.handle.net/11449/105563
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.sourceAleph
dc.subjectReabilitação bucalpt
dc.subjectImplantes dentáriospt
dc.subjectBiomecânicapt
dc.subjectCerâmica odontológicapt
dc.subjectMouth rehabilitationpt
dc.titleAvaliação da confiabilidade e modo de falha de coroas cerâmicas parafusadas a implantes osseointegráveis de diferentes conexõespt
dc.typeTese de doutoradopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes4438747643373395
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.graduateProgramOdontologia - FOApt
unesp.knowledgeAreaPrótese dentáriapt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
delben_ja_dr_araca.pdf
Tamanho:
2.1 MB
Formato:
Adobe Portable Document Format