Logo do repositório
 

Influence of pre-heat treatment and different light-curing units on Vickers hardness of a microhybrid composite resin

dc.contributor.authorSaade, E. G.
dc.contributor.authorBandeca, M. C.
dc.contributor.authorRastelli, Alessandra Nara de Souza [UNESP]
dc.contributor.authorBagnato, V. S.
dc.contributor.authorPorto-Neto, S. T.
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:23:54Z
dc.date.available2014-05-27T11:23:54Z
dc.date.issued2009-06-01
dc.description.abstractThe aim of this study was to evaluate the hardness of a dental composite resin submitted to temperature changes before photo-activation with two light-curing unite (LCUs). Five samples (4 mm in diameter and 2 mm in thickness) for each group were made with pre-cure temperatures of 37, 54, and 60°C. The samples were photo-activated with a conventional quartz-tungsten-halogen (QTH) and blue LED LCUs during 40 s. The hardness Vickers test (VHN) was performed on the top and bottom surfaces of the samples. According to the interaction between light-curing unit and different pre-heating temperatures of composite resin, only the light-curing unit provided influences on the mean values of initial Vickers hardness. The light-curing unit based on blue LED showed hardness mean values more homogeneous between the top and bottom surfaces. The hardness mean values were not statistically significant difference for the pre-cure temperature used. According to these results, the pre-heating of the composite resin provide no influence on Vickers hardness mean values, however the blue LED showed a cure more homogeneous than QTH LCU. © 2009 Pleiades Publishing, Ltd.en
dc.description.affiliationAraraquara School of Dentistry Department of Restorative Dentistry University of São Paulo State, Rua Humaitá, 1680, 14801-903, Araraquara-SP
dc.description.affiliationPhysics Institute of São Paulo University of São Paulo, Avenida Trabalhador São Carlense 400, 13560-970 São Carlos-SP
dc.format.extent1276-1281
dc.identifierhttp://dx.doi.org/10.1134/S1054660X09060164
dc.identifier.citationLaser Physics, v. 19, n. 6, p. 1276-1281, 2009.
dc.identifier.doi10.1134/S1054660X09060164
dc.identifier.issn1054-660X
dc.identifier.issn1555-6611
dc.identifier.lattes6914969526213393
dc.identifier.scopus2-s2.0-67049086346
dc.identifier.urihttp://hdl.handle.net/11449/71014
dc.language.isoeng
dc.relation.ispartofLaser Physics
dc.relation.ispartofjcr1.158
dc.relation.ispartofsjr0,345
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.subjectBlue LEDs
dc.subjectBottom surfaces
dc.subjectComposite resins
dc.subjectCure temperature
dc.subjectDental composite resins
dc.subjectLight curing
dc.subjectLight-curing units
dc.subjectMean values
dc.subjectPhoto-activated
dc.subjectPre-heat treatment
dc.subjectQuartz tungsten halogen
dc.subjectStatistically significant difference
dc.subjectTemperature changes
dc.subjectVickers
dc.subjectCuring
dc.subjectDental composites
dc.subjectHeating
dc.subjectOxide minerals
dc.subjectQuartz
dc.subjectResins
dc.subjectTungsten
dc.subjectVickers hardness
dc.titleInfluence of pre-heat treatment and different light-curing units on Vickers hardness of a microhybrid composite resinen
dc.typeArtigopt
dcterms.licensehttp://www.springer.com/open+access/authors+rights
dspace.entity.typePublication
relation.isDepartmentOfPublication901124bf-5736-4432-b057-7c29dec84b50
relation.isDepartmentOfPublication.latestForDiscovery901124bf-5736-4432-b057-7c29dec84b50
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes6914969526213393[3]
unesp.author.orcid0000-0002-6768-2670[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos