Logotipo do repositório
 

Publicação:
Eight-Year Follow-Up of a Fixed-Detachable Maxillary Prosthesis Utilizing an Attachment System: Clinical Protocol for Individuals With Skeletal Class III Malocclusions

dc.contributor.authorAvila, Erica Dorigatti de [UNESP]
dc.contributor.authorBorelli de Barros, Luiz Antonio [UNESP]
dc.contributor.authorDel'Acqua, Marcelo Antonialli
dc.contributor.authorNogueira, Sergio Sualdini [UNESP]
dc.contributor.authorMollo, Francisco de Assis [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionAraraquara Univ Ctr UNIARA
dc.date.accessioned2014-12-03T13:10:49Z
dc.date.available2014-12-03T13:10:49Z
dc.date.issued2014-06-01
dc.description.abstractThe aim of this article is to describe a successful clinical protocol for prosthodontic rehabilitation of a patient with a skeletal Class III malocclusion using a fixed-detachable maxillary prosthesis supported by 6 implants and the MK1 attachment system. The patient was followed up for 8 years. A 46-year-old edentulous woman with a skeletal Class III malocclusion expressed dissatisfaction with her old existing maxillary denture from an esthetic point of view and frustration regarding its function. A fixed-detachable maxillary prosthesis using the MK1 attachment system was made. The patient was followed up clinically and radiographically for 8 years. No bone loss, fracture of prosthetic components, or fracture of the prosthesis was detected in that period. A fixed detachable maxillary prosthesis using the MK1 attachment system is a treatment option for patients with Class III malocclusions who opt not to undergo orthognathic surgery.en
dc.description.affiliationUniv Estadual Paulista, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, Araraquara Dent Sch, Dept Social Odontol, Sao Paulo, Brazil
dc.description.affiliationAraraquara Univ Ctr UNIARA, Sao Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Araraquara Dent Sch, Dept Social Odontol, Sao Paulo, Brazil
dc.format.extent307-312
dc.identifierhttp://dx.doi.org/10.1563/AAID-JOI-D-11-00195
dc.identifier.citationJournal Of Oral Implantology. Lawrence: Allen Press Inc, v. 40, n. 3, p. 307-312, 2014.
dc.identifier.doi10.1563/AAID-JOI-D-11-00195
dc.identifier.issn0160-6972
dc.identifier.lattes0872749896035329
dc.identifier.urihttp://hdl.handle.net/11449/112555
dc.identifier.wosWOS:000337779900012
dc.language.isoeng
dc.publisherAllen Press Inc
dc.relation.ispartofJournal of Oral Implantology
dc.relation.ispartofjcr1.212
dc.relation.ispartofsjr0,569
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectattachment systemsen
dc.subjectdental implantsen
dc.subjectoverdenturesen
dc.titleEight-Year Follow-Up of a Fixed-Detachable Maxillary Prosthesis Utilizing an Attachment System: Clinical Protocol for Individuals With Skeletal Class III Malocclusionsen
dc.typeArtigo
dcterms.rightsHolderAllen Press Inc
dspace.entity.typePublication
unesp.author.lattes0872749896035329
unesp.author.orcid0000-0003-0742-2145[5]
unesp.author.orcid0000-0001-6681-1269[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt
unesp.departmentOdontologia Social - FOARpt

Arquivos