Publicação: Evaluation of the Bond Strength of Denture Base Resins to Acrylic Resin Teeth: Effect of Thermocycling
dc.contributor.author | Marra, Julie | |
dc.contributor.author | de Souza, Raphael Freitas | |
dc.contributor.author | Barbosa, Débora de Barros [UNESP] | |
dc.contributor.author | Pero, Ana Carolina [UNESP] [UNESP] | |
dc.contributor.author | Compagnoni, Marco Antonio [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2013-09-30T18:32:55Z | |
dc.date.accessioned | 2014-05-20T13:43:33Z | |
dc.date.available | 2013-09-30T18:32:55Z | |
dc.date.available | 2014-05-20T13:43:33Z | |
dc.date.issued | 2009-07-01 | |
dc.description.abstract | Purpose: The purpose of this study was to evaluate the thermocycling effects and shear bond strength of acrylic resin teeth to denture base resins.Materials and Methods: Three acrylic teeth (Biotone, Trilux, Ivoclar) were chosen for bonding to four denture base resins: microwave-polymerized (Acron MC), heat-polymerized (Lucitone 550 and QC-20), and light-polymerized (Versyo. bond). Twenty specimens were produced for each denture base/acrylic tooth combination and were divided into two groups (n = 10): without thermocycling (control groups) and thermocycled groups submitted to 5000 cycles between 4 and 60 degrees C. Shear strength tests (MPa) were performed with a universal testing machine at a crosshead speed of 1 mm/min. Statistical analysis of the results was carried out with three-way ANOVA and Bonferroni's multiple comparisons post hoc analysis for test groups (alpha = 0.05).Results: The shear bond strengths of Lucitone/Biotone, Lucitone/Trilux, and Versyo/Ivoclar specimens were significantly decreased by thermocycling, compared with the corresponding control groups (p < 0.05). The means of Acron/Ivoclar and Lucitone/Ivoclar specimens increased after thermocycling (p < 0.05). The highest mean shear bond strength value was observed with Lucitone/Biotone in the control group (14.54 MPa) and the lowest with QC-20/Trilux in the thermocycled group (3.69 MPa).Conclusion: Some acrylic tooth/denture base resin combinations can be more affected by thermocycling; effects vary based upon the materials used. | en |
dc.description.affiliation | São Paulo State Univ, UNESP, Dept Dent Mat & Prosthodont, Araraquara Dent Sch,Fac Odontol Araraquara, BR-14801903 São Paulo, Brazil | |
dc.description.affiliation | Univ São Paulo, Dept Dent Mat & Prosthodont, Ribeirao Preto Dent Sch, São Paulo, Brazil | |
dc.description.affiliation | São Paulo State Univ, UNESP, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, BR-14801903 São Paulo, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Dept Dent Mat & Prosthodont, Araraquara Dent Sch,Fac Odontol Araraquara, BR-14801903 São Paulo, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, BR-14801903 São Paulo, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 04/07855-2 | |
dc.format.extent | 438-443 | |
dc.identifier | http://dx.doi.org/10.1111/j.1532-849X.2009.00478.x | |
dc.identifier.citation | Journal of Prosthodontics-implant Esthetic and Reconstructive Dentistry. Malden: Wiley-blackwell, v. 18, n. 5, p. 438-443, 2009. | |
dc.identifier.doi | 10.1111/j.1532-849X.2009.00478.x | |
dc.identifier.issn | 1059-941X | |
dc.identifier.lattes | 7601364286525384 | |
dc.identifier.uri | http://hdl.handle.net/11449/15205 | |
dc.identifier.wos | WOS:000207914500012 | |
dc.language.iso | eng | |
dc.publisher | Wiley-Blackwell | |
dc.relation.ispartof | Journal of Prosthodontics-implant Esthetic and Reconstructive Dentistry | |
dc.relation.ispartofjcr | 1.745 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Web of Science | |
dc.subject | Shear strength | en |
dc.subject | acrylic resins | en |
dc.subject | artificial tooth | en |
dc.subject | dental materials | en |
dc.title | Evaluation of the Bond Strength of Denture Base Resins to Acrylic Resin Teeth: Effect of Thermocycling | en |
dc.type | Artigo | pt |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dcterms.rightsHolder | Wiley-blackwell | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication | 3936e2e2-946a-42ab-8b9d-9521513200fc | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 8921196002764597 | |
unesp.author.lattes | 2999722781960616[4] | |
unesp.author.orcid | 0000-0002-0203-2386[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: