Publicação: Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry
dc.contributor.author | Micheletti, J. K. [UNESP] | |
dc.contributor.author | Andersen, L. L. | |
dc.contributor.author | Machado, A. F. | |
dc.contributor.author | Lopes, J. S.S. | |
dc.contributor.author | Souto, L. R. | |
dc.contributor.author | Pastre, C. M. [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | National Research Centre for the Working Environment | |
dc.contributor.institution | Aalborg University | |
dc.contributor.institution | Jacarezinho | |
dc.contributor.institution | Mato Grosso | |
dc.date.accessioned | 2021-06-25T10:44:43Z | |
dc.date.available | 2021-06-25T10:44:43Z | |
dc.date.issued | 2021-06-01 | |
dc.description.abstract | Objective: To evaluate reliability of performance and metabolic expenditure during a shoulder abduction endurance test with isokinetic dynamometer. Methods: A total of 28 healthy adults participated in 4 sessions (Orientation, Familiarization, Test and Retest). The muscle endurance test was performed using 50% of the individual maximal isometric voluntary contraction strength (21.9 ± 5.8 Nm). Participants performed repeated 0–90° shoulder abductions until exhaustion in the isokinetic dynamometer at a velocity of 60°/s. Values of time, repetition, rhythm and total work were analyzed. Results: For test and retest, respectively, time to fatigue (seconds) was 95.5 ± 37.6 and 91.1 ± 32.8 (P = 0.27), and repetitions were 31.4 ± 12.1 and 29.9 ± 10.6 (P = 0.23). Reliability was satisfactory [Time: ICC = 0.83 (95% CI = 0.66; 0.92); Repetition: ICC = 0.83 (95% CI = 0. 67; 0.92); Rhythm: ICC = 0.55 (95% CI = 0.24; 0.77); Total work: ICC = 0.85 (95% CI = 0.69; 0.93)]. Conclusion: The isokinetic test for shoulder muscle endurance at 50% of maximal muscle strength has good reliability. | en |
dc.description.affiliation | Physiotherapy Department São Paulo State University (UNESP), 305, Roberto Simonsen, Presidente Prudente | |
dc.description.affiliation | National Research Centre for the Working Environment, Lersø Parkalle 105 | |
dc.description.affiliation | Sport Sciences Department of Health Science and Technology Aalborg University | |
dc.description.affiliation | Physiotherapy Department Universidade Estadual do Norte do Paraná (UENP) Jacarezinho | |
dc.description.affiliation | Federal University of Mato Grosso (UFMT) Mato Grosso | |
dc.description.affiliationUnesp | Physiotherapy Department São Paulo State University (UNESP), 305, Roberto Simonsen, Presidente Prudente | |
dc.format.extent | e111-e119 | |
dc.identifier | http://dx.doi.org/10.1016/j.scispo.2020.09.005 | |
dc.identifier.citation | Science and Sports, v. 36, n. 3, p. e111-e119, 2021. | |
dc.identifier.doi | 10.1016/j.scispo.2020.09.005 | |
dc.identifier.issn | 1778-4131 | |
dc.identifier.issn | 0765-1597 | |
dc.identifier.scopus | 2-s2.0-85096125707 | |
dc.identifier.uri | http://hdl.handle.net/11449/206840 | |
dc.language.iso | eng | |
dc.language.iso | fra | |
dc.relation.ispartof | Science and Sports | |
dc.source | Scopus | |
dc.subject | Fatigue | |
dc.subject | Muscle strength dynamometer | |
dc.subject | Reproducibility of results | |
dc.subject | Resistance training | |
dc.title | Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry | en |
dc.title | Évaluation de la fiabilité de la mesure d'endurance musculaire de l'abduction de l’épaule à l'aide d'un dynamomètre isocinétique | fr |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.department | Fisioterapia - FCT | pt |