Logotipo do repositório
 

Publicação:
Thermocycling effect on microhardness of laboratory composite resins

dc.contributor.authorPereira, Sarina Maciel Braga [UNESP]
dc.contributor.authorCastilho, Anderson Almeida [UNESP]
dc.contributor.authorSalazar-Marocho, Susana María [UNESP]
dc.contributor.authorOliveira, Karla Mychellyne Costa [UNESP]
dc.contributor.authorVáquez, Vanessa Zulema Ccahuana [UNESP]
dc.contributor.authorBottino, Marco Antonio [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:22:32Z
dc.date.available2014-05-27T11:22:32Z
dc.date.issued2007-07-01
dc.description.abstractTha aim of this study was to evaluate the thermocycling effect on microhardness of laboratory composite resins, 30 disks were fabricated, 5mm of diameter and 2mm of width, using 3 laboratory resins: G1 (n=10) - RESILAB MASTER (Wilcos-Brasil), G2 (n=10) - Vita VMLC (VITA Zahnfabrik-Germany), and G3 (n=10) - Vita Zeta (VITA Zahnfabrik-Germany). Vickers microhardness (HV) of all specimens was evaluated using a microhardness tester FM-700 (Future Tech- 50 g/10s). The specimens were measured before and after the thermocycling (3,000 times and 12,000 times - 5°/55°C±1). The microhardness values before cycling were (mean±SD): G1: 55.50±4.6; G2: 35.54±2.5; G3: 27.97±1.6; after 3,000 thermocycles: G1: 55.54±3.9; G2: 29.92±2.73; G3:21.01±1.4 and after 12,000 cycles G1: 54.27±3.2; G2: 30.91±1.6; G3: 23.81±0.9. Variance analysis (ANOVA) and Tukey's test was accomplished (p<0.05), the highest microhardness values were observed in G1: G2 and G3 showed reduction of microhardness values. It was concluded that, after thermocycling, the tested laboratory composites resins are susceptible to the decrease of surface microhardness.en
dc.description.affiliationDepartment of Dental Materials and Prostheses Paulista State University UNESP, São José dos Campos, SP
dc.description.affiliation, Rua Inconfidência 196, 12245-370 Sao Jose dos Campos, SP
dc.description.affiliationUnespDepartment of Dental Materials and Prostheses Paulista State University UNESP, São José dos Campos, SP
dc.format.extent1372-1375
dc.identifierhttp://www.bibliotecadigital.unicamp.br/document/?code=24151&print=y
dc.identifier.citationBrazilian Journal of Oral Sciences, v. 6, n. 22, p. 1372-1375, 2007.
dc.identifier.file2-s2.0-37249087910.pdf
dc.identifier.issn1677-3217
dc.identifier.issn1677-3225
dc.identifier.lattes9234456003563666
dc.identifier.scopus2-s2.0-37249087910
dc.identifier.urihttp://hdl.handle.net/11449/69774
dc.language.isoeng
dc.relation.ispartofBrazilian Journal of Oral Sciences
dc.relation.ispartofsjr0,131
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectComposite resins
dc.subjectMicrohardness
dc.subjectThermocycling
dc.titleThermocycling effect on microhardness of laboratory composite resinsen
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/bjos/iaboutj.htm
dspace.entity.typePublication
unesp.author.lattes9234456003563666
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-37249087910.pdf
Tamanho:
34.36 KB
Formato:
Adobe Portable Document Format