Logo do repositório
 

Clinical performance of a self-etching adhesive at 18 months

dc.contributor.authorPerdigao, J.
dc.contributor.authorCarmo, ARP
dc.contributor.authorAnauate-Netto, C.
dc.contributor.authorAmore, R.
dc.contributor.authorLewgoy, H. R.
dc.contributor.authorCordeiro, HJD
dc.contributor.authorDutra-Correa, M.
dc.contributor.authorCastilhos, N.
dc.contributor.institutionUniv Minnesota
dc.contributor.institutionUMC
dc.contributor.institutionUNIBAN
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUNICSUL
dc.date.accessioned2014-05-20T15:21:38Z
dc.date.available2014-05-20T15:21:38Z
dc.date.issued2005-04-01
dc.description.abstractPurpose: To test the null hypothesis that beveling and/or etching enamel would not affect the 18-month clinical performance of the self-etching adhesive Clearfil SE Bond (CSEB) in noncarious cervical lesions (NCCL). Methods: With Institutional Review Board approval, 34 patients were enrolled in this study. A total of 120 NCCL was selected and assigned to four groups: (1) CSEB was applied without any cavity preparation; (2) CSEB was applied after beveling enamel; (3) CSEB was applied after etching enamel for 15 seconds with 35% phosphoric acid; (4) CSEB was applied after beveling and etching enamel. A microfilled composite resin was used for all restorations. Resuts: At 6 months after initial placement, 120 restorations (a 100% recall rate) were evaluated. At 18 months, 87 restorations (a 72.5% recall rate) were available for evaluation. A survival rate of 100% was measured for all groups at both 6 and 18 months. Sensitivity to air decreased significantly only for Group 3 (no bevel+acid etch) from baseline to 18 months without statistical changes from 6 months to 18 months. None of the other parameters resulted in significant differences for any of the four groups. However, when data were pooled, both the overall marginal discoloration and the overall marginal adaptation were significantly worse at 18 months than at baseline, while sensitivity to air decreased significantly from baseline to 18 months. The 18-month survival rate of the self-etching adhesive Clearfil SE Bond was not improved by enamel bevel or by enamel etching. Both overall marginal adaptation and overall marginal discoloration were worse at 18 months than at baseline.en
dc.description.affiliationUniv Minnesota, Sch Dent, Div Operat Dent, Dept Restorat Sci, Minneapolis, MN 55455 USA
dc.description.affiliationUMC, Dept Operat Dent, Mogi Das Cruzes, SP, Brazil
dc.description.affiliationUNIBAN, Dept Operat Dent, São Paulo, Brazil
dc.description.affiliationUNESP, Dept Operat Dent, Sao Jose Dos Campos, Brazil
dc.description.affiliationUNICSUL, São Paulo, Brazil
dc.description.affiliationUnespUNESP, Dept Operat Dent, Sao Jose Dos Campos, Brazil
dc.format.extent135-140
dc.identifierhttp://www.amjdent.com/previousarticles.htm
dc.identifier.citationAmerican Journal of Dentistry. Weston: Mosher & Linder, Inc., v. 18, n. 2, p. 135-140, 2005.
dc.identifier.issn0894-8275
dc.identifier.urihttp://hdl.handle.net/11449/32767
dc.identifier.wosWOS:000229092000013
dc.language.isoeng
dc.publisherMosher & Linder, Inc
dc.relation.ispartofAmerican Journal of Dentistry
dc.relation.ispartofjcr0.760
dc.relation.ispartofsjr0,509
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.titleClinical performance of a self-etching adhesive at 18 monthsen
dc.typeArtigopt
dcterms.licensehttp://www.amjdent.com/AJDInformationforAuthors-709.pdf
dcterms.rightsHolderMosher & Linder, Inc
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt

Arquivos

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: