Logotipo do repositório
 

Publicação:
Mechanical behavior of different micro conical abutments in fixed prosthesis

dc.contributor.authorTribst, João Paulo Mendes [UNESP]
dc.contributor.authorde Melo, Renata Marques [UNESP]
dc.contributor.authorBorges, Alexandre Luiz Souto [UNESP]
dc.contributor.authorde Assunção e Souza, Rodrigo Othávio
dc.contributor.authorBottino, Marco Antonio [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionVrije Universiteit
dc.contributor.institutionFederal University of Rio Grande do Norte (UFRN)
dc.date.accessioned2019-10-06T16:55:29Z
dc.date.available2019-10-06T16:55:29Z
dc.date.issued2018-01-01
dc.description.abstractPurpose: To evaluate the biomechanical behavior between two different micro conical abutments: two-piece and one-piece abutments. Materials and Methods: Four groups were divided according to the prosthetic connection (internal or external hexagon) and abutment type. The vertical misfit between the abutment and implant was evaluated under stereomicroscope. Next, the implants were divided into pairs and embedded in polyurethane to receive two-element prostheses. The initial removal torque was measured for abutments and for prosthesis fixation. The samples were mechanically cycled (200 N, 2 Hz, 2 × 10 6 cycles) before measuring the torque loss in the same regions. For stress verification, a finite element analysis was used. Results: For vertical misfit, one-piece (4.70 ± 0.26 μm) < two-piece (16.8 ± 0.32 μm). For preload in abutment screw, two-piece = one-piece. For prosthetic screw, a higher percentage of preload was found for two-piece, but no statistical difference was observed after fatigue cycling between the groups. For stress analysis, no difference (10%) was observed for abutments, retention screw, or for the bone. Conclusion: The one-piece abutment maintained even amounts of preload after cyclic loading and presented less vertical misfit in comparison with the two-piece abutment for both implant connections. The use of one-piece abutments did not increase the stress and strain concentration, suggesting acceptable biomechanical behavior.en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics São Paulo State University (UNESP) Institute of Science and Technology
dc.description.affiliationDepartment of Dental Materials Science Academic Centre for Dentistry Amsterdam (ACTA) Universiteit van Amsterdam Vrije Universiteit
dc.description.affiliationDepartment of Dentistry Federal University of Rio Grande do Norte (UFRN)
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics São Paulo State University (UNESP) Institute of Science and Technology
dc.format.extent1199-1205
dc.identifierhttp://dx.doi.org/10.11607/jomi.6578
dc.identifier.citationInternational Journal of Oral and Maxillofacial Implants, v. 33, n. 6, p. 1199-1205, 2018.
dc.identifier.doi10.11607/jomi.6578
dc.identifier.issn0882-2786
dc.identifier.lattes9234456003563666
dc.identifier.scopus2-s2.0-85056731946
dc.identifier.urihttp://hdl.handle.net/11449/189889
dc.language.isoeng
dc.relation.ispartofInternational Journal of Oral and Maxillofacial Implants
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.subjectAbutments
dc.subjectDental implants
dc.subjectFinite element analysis
dc.subjectImplant-abutment interface
dc.subjectNonlinear analysis
dc.subjectTorque loss
dc.titleMechanical behavior of different micro conical abutments in fixed prosthesisen
dc.typeArtigo
dspace.entity.typePublication
unesp.advisor.lattes9234456003563666
unesp.author.lattes6043459304176015[3]
unesp.author.orcid0000-0002-5707-7565[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt

Arquivos