Publicação: Copper determination in ethanol fuel by differential pulse anodic stripping voltammetry at a solid paraffin-based carbon paste electrode modified with 2-aminothiazole organofunctionalized silica
dc.contributor.author | Takeuchi, Regina M. | |
dc.contributor.author | Santos, Andre L. | |
dc.contributor.author | Padilha, Pedro M. | |
dc.contributor.author | Stradiotto, Nelson Ramos [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T13:53:20Z | |
dc.date.available | 2014-05-20T13:53:20Z | |
dc.date.issued | 2007-02-15 | |
dc.description.abstract | Solid paraffin-based carbon paste electrodes modified with 2-aminothiazole organofunctionalized silica have been applied to the anodic stripping determination of copper ions in ethanol fuel samples without any sample treatment. The proposed method comprised four steps: (1) copper ions preconcentration at open circuit potential directly in the ethanol fuel sample; (2) exchange of the solution and immediate cathodic reduction of the absorbate at controlled potential; (3) differential pulse anodic stripping voltammetry; (4) electrochemical surface regeneration by applying a positive potential in acid media. Factors affecting the preconcentration, reduction and stripping steps were investigated and the optimum conditions were employed to develop the analytical procedure. Using a preconcentration time of 20 min and reduction time of 120 s at -0.3 V versus Ag/AgCl(sat) a linear range from 7.5 x 10(-8) to 2.5 x 10(-6) mol L(-1) with detection limit of 3.1 x 10(-8) mol L(-1) was obtained. Interference studies have shown a decrease in the interference effect according to the sequence: Ni > Zn > Cd > Pb > Fe. However, the interference effects of these ions have not forbidden the application of the proposed method. Recovery values between 98.8 and 102.3% were obtained for synthetic samples spiked with known amounts of Cu(2+) and interfering metallic ions. The developed electrode was successfully applied to the determination of Cu(2+) in commercial ethanol fuel samples. The results were compared to those obtained by flame atomic absorption spectroscopy by using the F-test and t-test. Neither F-value nor t-value have exceeded the critical values at 95% confidence level, confirming that there are no significant differences between the results obtained by both methods. (c) 2006 Elsevier B.V. All rights reserved. | en |
dc.description.affiliation | UNESP, Inst Quim, Dept Quim Analit, Araraquara, Brazil | |
dc.description.affiliation | UNESP, IB, Dept Quim & Bioquim, Botucatu, SP, Brazil | |
dc.description.affiliationUnesp | UNESP, Inst Quim, Dept Quim Analit, Araraquara, Brazil | |
dc.description.affiliationUnesp | UNESP, IB, Dept Quim & Bioquim, Botucatu, SP, Brazil | |
dc.format.extent | 771-777 | |
dc.identifier | http://dx.doi.org/10.1016/j.talanta.2006.05.035 | |
dc.identifier.citation | Talanta. Amsterdam: Elsevier B.V., v. 71, n. 2, p. 771-777, 2007. | |
dc.identifier.doi | 10.1016/j.talanta.2006.05.035 | |
dc.identifier.issn | 0039-9140 | |
dc.identifier.lattes | 6981448637456391 | |
dc.identifier.lattes | 0072173018005712 | |
dc.identifier.orcid | 0000-0003-4179-0574 | |
dc.identifier.uri | http://hdl.handle.net/11449/19035 | |
dc.identifier.wos | WOS:000244369600039 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | Talanta | |
dc.relation.ispartofjcr | 4.244 | |
dc.relation.ispartofsjr | 1,186 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | ethanol fuel | pt |
dc.subject | solid paraffin-based carbon paste electrodes | pt |
dc.subject | organofunctionalized silica | pt |
dc.subject | copper ions | pt |
dc.subject | differential pulse stripping voltammetry | pt |
dc.title | Copper determination in ethanol fuel by differential pulse anodic stripping voltammetry at a solid paraffin-based carbon paste electrode modified with 2-aminothiazole organofunctionalized silica | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. | |
dspace.entity.type | Publication | |
unesp.author.lattes | 6981448637456391[3] | |
unesp.author.lattes | 0072173018005712 | |
unesp.author.orcid | 0000-0002-8779-9585[4] | |
unesp.author.orcid | 0000-0002-2856-1059[2] | |
unesp.author.orcid | 0000-0003-4179-0574[3] | |
unesp.author.orcid | 0000-0002-1227-5242[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Biociências, Botucatu | pt |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química e Bioquímica - IBB | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: