Logotipo do repositório
 

Publicação:
Analysis of adhesive bond strength under simulated pulpal pressure during laser irradiation on different dentin thicknesses

dc.contributor.authorHaddad, Bruno Do Amaral [UNESP]
dc.contributor.authorda SILVA, Tânia Mara [UNESP]
dc.contributor.authorGonçalves, Lucélia Lemes [UNESP]
dc.contributor.authorSilva, Mateus Rodrigues [UNESP]
dc.contributor.authorJunior, Cláudio Moreira [UNESP]
dc.contributor.authorde SANTIS, Leandro Ruivo [UNESP]
dc.contributor.authorGonçalves, Sérgio Eduardo de Paiva [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2020-12-12T01:56:18Z
dc.date.available2020-12-12T01:56:18Z
dc.date.issued2020-01-01
dc.description.abstractObjective: Evaluate the microtensile bond strength (µTBS) in different dentin thicknesses, under simulated pulpal pressure (SPP), submitted to an adhesive technique using laser irradiation. Material and methods: Forty sound human molars were sectioned and randomly divided into two groups (n=20): Group 1 – 1 mm of dentin thickness; Group 2 – 2 mm of dentin thickness. Each group was divided into two subgroups (n=10): Subgroup A – Absence of SPP; Subgroup P – Presence of SPP (15 cm H2 O). The samples were sequentially treated with: 37% phosphoric acid, adhesive system (Adper Single Bond 2), Nd:YAG laser irradiation (60 s, 1064 nm, 10 Hz) using 60 and 100 mJ/pulse energy parameters and photopolymerization (10 s). A composite resin block (Filtek Z350) was built up onto the irradiated area. After 30 days stored in water, the samples were sectioned and submitted to microtensile test (10 kgf load cell, 0.5mm/min). Data were analyzed by two-way ANOVA and Tukey tests. Results: Two-way ANOVA revealed no significant differences for SPP on bond strength. The laser energy parameters indicated that 100 mJ showed greater µTBS means compared to the group irradiated with 60 mJ. The presence of SPP reduced the mean µTBS values. Conclusions: Simulated pulpal pressure did not affect the µTBS using 60 mJ of laser energy parameter. At 100 mJ, the presence of SPP negatively influenced the bond strength, regardless of dentin thickness.en
dc.description.affiliationSao Paulo State University (Unesp) Institute of Science and Technology São José dos Campos Department of Restorative Dentistry
dc.description.affiliationUnespSao Paulo State University (Unesp) Institute of Science and Technology São José dos Campos Department of Restorative Dentistry
dc.identifierhttp://dx.doi.org/10.14295/bds.2020.v23i1.1858
dc.identifier.citationBrazilian Dental Science, v. 23, n. 1, 2020.
dc.identifier.doi10.14295/bds.2020.v23i1.1858
dc.identifier.issn2178-6011
dc.identifier.scopus2-s2.0-85079193026
dc.identifier.urihttp://hdl.handle.net/11449/200053
dc.language.isoeng
dc.relation.ispartofBrazilian Dental Science
dc.sourceScopus
dc.subjectBond strength
dc.subjectDentin
dc.subjectIntrapulpal pressure
dc.subjectNd:YAG laser
dc.titleAnalysis of adhesive bond strength under simulated pulpal pressure during laser irradiation on different dentin thicknessesen
dc.titleAnálise da resistência adesiva sob pressão pulpar simulada durante irradiação laser em diferentes espessuras de dentinapt
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentOdontologia Restauradora - ICTpt

Arquivos