Logotipo do repositório
 

Publicação:
Influence of Tube Current Settings on Diagnostic Detection of Root Fractures Using Cone-beam Computed Tomography: An In Vitro Study

dc.contributor.authorTangari-Meira, Ricardo [UNESP]
dc.contributor.authorVancetto, José Ricardo [UNESP]
dc.contributor.authorDovigo, Lívia Nordi [UNESP]
dc.contributor.authorTosoni, Guilherme Monteiro [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:15:55Z
dc.date.available2018-12-11T17:15:55Z
dc.date.issued2017-10-01
dc.description.abstractIntroduction This study assessed the influence of tube current settings (milliamperes [mA]) on the diagnostic detection of root fractures (RFs) using cone-beam computed tomographic (CBCT) imaging. Method Sixty-eight human anterior and posterior teeth were submitted to root canal preparation, and 34 root canals were filled. The teeth were divided into 2 groups: the control group and the fractured group. RFs were induced using a universal mechanical testing machine; afterward, the teeth were placed in a phantom. Images were acquired using a Scanora 3DX unit (Soredex, Tuusula, Finland) with 5 different mA settings: 4.0, 5.0, 6.3, 8.0, and 10.0. Two examiners (E1 and E2) classified the images according to a 5-point confidence scale. Intra- and interexaminer reproducibility was assessed using the kappa statistic; diagnostic performance was assessed using the area under the receiver operating characteristic curve (AUROC). Results Intra- and interexaminer reproducibility showed substantial (κE1 = 0.791 and κE2 = 0.695) and moderate (κE1 × E2 = 0.545) agreement, respectively. AUROC was significantly higher (P ≤ .0389) at 8.0 and 10.0 mA and showed no statistical difference between the 2 tube current settings. Conclusions Tube current has a significant influence on the diagnostic detection of RFs in CBCT images. Despite the acceptable diagnosis of RFs using 4.0 and 5.0 mA, those settings had lower discrimination abilities when compared with settings of 8.0 and 10.0 mA.en
dc.description.affiliationDepartment of Oral Diagnosis and Surgery School of Dentistry São Paulo State University (Unesp)
dc.description.affiliationDepartment of Social Dentistry Araraquara Dental School São Paulo State University
dc.description.affiliationUnespDepartment of Oral Diagnosis and Surgery School of Dentistry São Paulo State University (Unesp)
dc.description.affiliationUnespDepartment of Social Dentistry Araraquara Dental School São Paulo State University
dc.format.extent1701-1705
dc.identifierhttp://dx.doi.org/10.1016/j.joen.2017.05.008
dc.identifier.citationJournal of Endodontics, v. 43, n. 10, p. 1701-1705, 2017.
dc.identifier.doi10.1016/j.joen.2017.05.008
dc.identifier.file2-s2.0-85033401468.pdf
dc.identifier.issn0099-2399
dc.identifier.lattes0127570480681342
dc.identifier.scopus2-s2.0-85033401468
dc.identifier.urihttp://hdl.handle.net/11449/175459
dc.language.isoeng
dc.relation.ispartofJournal of Endodontics
dc.relation.ispartofsjr1,585
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectCone-beam computed tomographic imaging
dc.subjectdiagnostic imaging
dc.subjectroot fractures
dc.subjecttube current
dc.titleInfluence of Tube Current Settings on Diagnostic Detection of Root Fractures Using Cone-beam Computed Tomography: An In Vitro Studyen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes0127570480681342
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Social - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-85033401468.pdf
Tamanho:
568.68 KB
Formato:
Adobe Portable Document Format
Descrição: