Publicação: Effect of thermal cycling and disinfection on colour stability of denture base acrylic resin
dc.contributor.author | Goiato, Marcelo Coelho [UNESP] | |
dc.contributor.author | Santos, Daniela Micheline dos [UNESP] | |
dc.contributor.author | Baptista, Gabriella T. | |
dc.contributor.author | Moreno, Amália | |
dc.contributor.author | Andreotti, Agda M. | |
dc.contributor.author | Bannwart, Lisiane C. | |
dc.contributor.author | Dekon, Stefan F.C. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-27T11:26:27Z | |
dc.date.available | 2014-05-27T11:26:27Z | |
dc.date.issued | 2012-04-25 | |
dc.description.abstract | Objectives: The purpose of this study was to investigate the effect of thermal cycling and disinfection on the colour change of denture base acrylic resin. Materials and Methods: Four different brands of acrylic resins were evaluated (Onda Cryl, QC 20, Classico and Lucitone). All brands were divided into four groups (n=7) determined according to the disinfection procedure (microwave, Efferdent, 4% chlorhexidine or 1% hypochlorite). The treatments were conducted three times a week for 60days. All specimens were thermal cycled between 5 and 55°C with 30-s dwell times for 1000 cycles before and after disinfection. The specimens' colour was measured with a spectrophotometer using the CIE L*a*b* system. The evaluations were conducted at baseline (B), after first thermal cycling (T 1), after disinfection (D) and after second thermal cycling (T 2). Colour differences (ΔE) were calculated between T 1 and B (T 1B), D and B (DB), and T 2 and B (T 2B) time-points. Results: The samples submitted to disinfection by microwave and Efferdent exhibited the highest values of colour change. There were significant differences on colour change between the time-points, except for the Lucitone acrylic resin. Conclusions: The thermal cycling and disinfection procedures significantly affected the colour stability of the samples. However, all values obtained for the acrylic resins are within acceptable clinical parameters. © 2012 The Gerodontology Society and John Wiley & Sons A/S. | en |
dc.identifier | http://dx.doi.org/10.1111/j.1741-2358.2012.00676.x | |
dc.identifier.citation | Gerodontology. | |
dc.identifier.doi | 10.1111/j.1741-2358.2012.00676.x | |
dc.identifier.issn | 0734-0664 | |
dc.identifier.issn | 1741-2358 | |
dc.identifier.lattes | 9719883814872582 | |
dc.identifier.orcid | 0000-0002-3800-3050 | |
dc.identifier.scopus | 2-s2.0-84859928479 | |
dc.identifier.uri | http://hdl.handle.net/11449/73293 | |
dc.identifier.wos | WOS:000328290500006 | |
dc.language.iso | eng | |
dc.relation.ispartof | Gerodontology | |
dc.relation.ispartofjcr | 1.439 | |
dc.relation.ispartofsjr | 0,627 | |
dc.relation.ispartofsjr | 0,627 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Scopus | |
dc.subject | Acrylic resins | |
dc.subject | Colour stability | |
dc.subject | Disinfection | |
dc.title | Effect of thermal cycling and disinfection on colour stability of denture base acrylic resin | en |
dc.type | Artigo | pt |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 9719883814872582 | |
unesp.author.orcid | 0000-0002-3800-3050[1] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |