Logotipo do repositório
 

Publicação:
Effect of thermal cycling and disinfection on colour stability of denture base acrylic resin

dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.authorSantos, Daniela Micheline dos [UNESP]
dc.contributor.authorBaptista, Gabriella T.
dc.contributor.authorMoreno, Amália
dc.contributor.authorAndreotti, Agda M.
dc.contributor.authorBannwart, Lisiane C.
dc.contributor.authorDekon, Stefan F.C.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:26:27Z
dc.date.available2014-05-27T11:26:27Z
dc.date.issued2012-04-25
dc.description.abstractObjectives: The purpose of this study was to investigate the effect of thermal cycling and disinfection on the colour change of denture base acrylic resin. Materials and Methods: Four different brands of acrylic resins were evaluated (Onda Cryl, QC 20, Classico and Lucitone). All brands were divided into four groups (n=7) determined according to the disinfection procedure (microwave, Efferdent, 4% chlorhexidine or 1% hypochlorite). The treatments were conducted three times a week for 60days. All specimens were thermal cycled between 5 and 55°C with 30-s dwell times for 1000 cycles before and after disinfection. The specimens' colour was measured with a spectrophotometer using the CIE L*a*b* system. The evaluations were conducted at baseline (B), after first thermal cycling (T 1), after disinfection (D) and after second thermal cycling (T 2). Colour differences (ΔE) were calculated between T 1 and B (T 1B), D and B (DB), and T 2 and B (T 2B) time-points. Results: The samples submitted to disinfection by microwave and Efferdent exhibited the highest values of colour change. There were significant differences on colour change between the time-points, except for the Lucitone acrylic resin. Conclusions: The thermal cycling and disinfection procedures significantly affected the colour stability of the samples. However, all values obtained for the acrylic resins are within acceptable clinical parameters. © 2012 The Gerodontology Society and John Wiley & Sons A/S.en
dc.identifierhttp://dx.doi.org/10.1111/j.1741-2358.2012.00676.x
dc.identifier.citationGerodontology.
dc.identifier.doi10.1111/j.1741-2358.2012.00676.x
dc.identifier.issn0734-0664
dc.identifier.issn1741-2358
dc.identifier.lattes9719883814872582
dc.identifier.orcid0000-0002-3800-3050
dc.identifier.scopus2-s2.0-84859928479
dc.identifier.urihttp://hdl.handle.net/11449/73293
dc.identifier.wosWOS:000328290500006
dc.language.isoeng
dc.relation.ispartofGerodontology
dc.relation.ispartofjcr1.439
dc.relation.ispartofsjr0,627
dc.relation.ispartofsjr0,627
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.subjectAcrylic resins
dc.subjectColour stability
dc.subjectDisinfection
dc.titleEffect of thermal cycling and disinfection on colour stability of denture base acrylic resinen
dc.typeArtigopt
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes9719883814872582
unesp.author.orcid0000-0002-3800-3050[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos