Logo do repositório
 

Estimativa do lançamento de água pluvial no sistema de coleta e transporte de esgoto sanitário por meio de práticas de aproveitamento em residências unifamiliares

dc.contributor.authorMoruzzi, Rodrigo Braga [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:28:00Z
dc.date.available2018-12-11T17:28:00Z
dc.date.issued2016-01-01
dc.description.abstractThe rainwater (rw) of harvesting systems used in households and commercial buildings comes from independent system, i.e. disconnected of drinking water system. So, rw is not directly measured by conventional drinking water meters which are installed in pipes from public system. Therefore, the used rw volumes are not properly measured. This paper presents a methodology to estimate rainwater loading discharged in sewage systems by means of harvesting practices in households. The estimation was indexed to the drinking water meter. The toilet flush was adopted as object analysis. Results pointed out that the efficiency of rw system varies from 24 to 87%, whose correspond to values varying from 8 a 370 L.inhab.-1.dia-1 keeping fixed reservoir volume of 0,5 m3inhab.-1 for all ranges of per capita consumption. The rw in sewage represented values lower than 30% of the total demand considering specific roof from 4 to 25 m2.inhab.-1. On the other hand, for reservoir of rw harvesting systems bigger than 3 m3.inhab.-1 15 m2 of roof.inhab.-1 was enough to plenty supply the toilet flush., based on 120 L.inhab.-1 consumption. In general terms, the correction factor proposed for estimating wastewater discharge on the new scenario (considering rw harvesting), varies from 1 to 1.42 (1≤(fcorrigido/f)≤1.42). So, the new ratio, given by wastewater and inlet drinking water, varied from 0.8 to 1.14 (0.8≤fcorrigido≤1.14).en
dc.description.affiliationUniversidade Estadual Paulista ‘Júlio de Mesquita Filho’ (Unesp)
dc.description.affiliationUnespUniversidade Estadual Paulista ‘Júlio de Mesquita Filho’ (Unesp)
dc.format.extent85-94
dc.identifierhttp://dx.doi.org/10.1590/S1413-41520201600100142009
dc.identifier.citationEngenharia Sanitaria e Ambiental, v. 21, n. 1, p. 85-94, 2016.
dc.identifier.doi10.1590/S1413-41520201600100142009
dc.identifier.fileS1413-41522016000100085.pdf
dc.identifier.issn1413-4152
dc.identifier.scieloS1413-41522016000100085
dc.identifier.scopus2-s2.0-84964237529
dc.identifier.urihttp://hdl.handle.net/11449/177972
dc.language.isopor
dc.relation.ispartofEngenharia Sanitaria e Ambiental
dc.relation.ispartofsjr0,218
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectEfficiency of attendance and harvesting
dc.subjectRainwater
dc.subjectSewage
dc.subjectSewage correction factor
dc.titleEstimativa do lançamento de água pluvial no sistema de coleta e transporte de esgoto sanitário por meio de práticas de aproveitamento em residências unifamiliarespt
dc.title.alternativeEstimating disposal of rainwater on sewage system by means of rainwater harvesting practices in householdsen
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Geociências e Ciências Exatas, Rio Claropt
unesp.departmentPlanejamento Territorial e Geoprocessamento - IGCEpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1413-41522016000100085.pdf
Tamanho:
1.05 MB
Formato:
Adobe Portable Document Format