Logotipo do repositório
 

Publicação:
Assessment of the Correlation Between Insertion Torque and Resonance Frequency Analysis of Implants Placed in Bone Tissue of Different Densities

dc.contributor.authorMagno Filho, Luiz Carlos [UNESP]
dc.contributor.authorCirano, Fabiano Ribeiro [UNESP]
dc.contributor.authorHayashi, Fernando [UNESP]
dc.contributor.authorFeng, Hsu Shao [UNESP]
dc.contributor.authorConte, Alexandre [UNESP]
dc.contributor.authorDib, Luciano Lauria [UNESP]
dc.contributor.authorCasati, Marcio Zaffalon [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-12-03T13:08:52Z
dc.date.available2014-12-03T13:08:52Z
dc.date.issued2014-06-01
dc.description.abstractThe primary stability of dental implants is fundamental for osseointegration. Therefore, this study aimed to assess the correlation between insertion torque (IT) and resonance frequency analysis (RFA) of implants placed in mandibles and maxillas of different bone densities. Eighty dental implants were placed in maxillas and mandibles, and IT and the implant stability quotient (ISQ) were measured at the time of implant insertion. Bone density was assessed subjectively by the Lekholm and Zarb index. The type I and II densities were grouped together (group A)as were the type III and IV densities (group B). The IT in group A was higher (Student t test, P = .0013) than in group B (46.27 +/- 18.51 Ncm, 33.62 +/- 14.74 Ncm, respectively). The implants placed in group A showed higher ISQ (Student t test, P = .0004) than those placed in group B (70.09 +/- 7.50, 63.66 +/- 8.00, respectively). A significant correlation between IT and the ISQ value was observed for group A (Pearson correlation test; r = 0.35; P = .0213) and for group B (r = 0.37; P = .0224). Within the limitations of this study, it was possible to conclude that there is a correlation between IT and RFA of implants placed in mandibles and maxillas of different bone densities.en
dc.description.affiliationUniv Estadual Paulista, Sao Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Sao Paulo, Brazil
dc.format.extent259-262
dc.identifierhttp://dx.doi.org/10.1563/AAID-JOI-D-11-00183
dc.identifier.citationJournal Of Oral Implantology. Lawrence: Allen Press Inc, v. 40, n. 3, p. 259-262, 2014.
dc.identifier.doi10.1563/AAID-JOI-D-11-00183
dc.identifier.issn0160-6972
dc.identifier.urihttp://hdl.handle.net/11449/111658
dc.identifier.wosWOS:000337779900005
dc.language.isoeng
dc.publisherAllen Press Inc
dc.relation.ispartofJournal of Oral Implantology
dc.relation.ispartofjcr1.212
dc.relation.ispartofsjr0,569
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectinsertion torqueen
dc.subjectdental implanten
dc.subjectbone densityen
dc.subjectRFAen
dc.titleAssessment of the Correlation Between Insertion Torque and Resonance Frequency Analysis of Implants Placed in Bone Tissue of Different Densitiesen
dc.typeArtigo
dcterms.rightsHolderAllen Press Inc
dspace.entity.typePublication
unesp.author.orcid0000-0002-7331-4612[2]
unesp.author.orcid0000-0001-6717-8303[6]