Logotipo do repositório
 

Publicação:
Validation of analytical methodology for quantification of cefazolin sodium by liquid chromatography

dc.contributor.authorPedroso, Tahisa Marcela [UNESP]
dc.contributor.authorSalgado, Hérida Regina Nunes [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2016-01-28T16:56:28Z
dc.date.available2016-01-28T16:56:28Z
dc.date.issued2014
dc.description.abstractA reversed-phase high performance liquid chromatography method was validated for the determination of cefazolin sodium in lyophilized powder for solution for injection to be applied for quality control in pharmaceutical industry. The liquid chromatography method was conducted on a Zorbax Eclipse Plus C18 column (250 x 4.6 mm, 5 μm), maintained at room temperature. The mobile phase consisted of purified water: acetonitrile (60: 40 v/v), adjusted to pH 8 with triethylamine. The flow rate was of 0.5 mL min-1 and effluents were monitored at 270 nm. The retention time for cefazolin sodium was 3.6 min. The method proved to be linear (r2 =0.9999) over the concentration range of 30-80 µg mL-1. The selectivity of the method was proven through degradation studies. The method demonstrated satisfactory results for precision, accuracy, limits of detection and quantitation. The robustness of this method was evaluated using the Plackett–Burman fractional factorial experimental design with a matrix of 15 experiments and the statistical treatment proposed by Youden and Steiner. Finally, the proposed method could be also an advantageous option for the analysis of cefazolin sodium, contributing to improve the quality control and to assure the therapeutic efficacyen
dc.description.abstractUm método cromatográfico em fase reversa foi validado para a determinação de cefazolina sódica em pó liofilizado, a ser aplicado no controle de qualidade em indústrias farmacêuticas. O método por cromatografia líquida foi conduzido em coluna Zorbax Eclipse Plus C18 (250 × 4,6 mm, 5 µm) mantida à temperatura ambiente. A fase móvel consistiu de água purificada: acetonitrila (60 : 40 v/v), com o pH ajustado para 8 com trietilamina. A vazão usada foi de 0,5 mL min-1 e os analitos de interesse foram monitorizados a 270 nm. O tempo de retenção da cefazolina sódica foi de 3,6 min. As áreas dos picos de cefazolina sódica foram lineares na faixa de concentração de 30-80 µg mL-1 (r2 = 0,9999). A seletividade do método foi demonstrada através de estudos de degradação. O método demonstrou resultados satisfatórios para precisão, exatidão, limites de detecção e de quantificação. A robustez do método foi avaliada utilizando o esquema fatorial de Plackett-Burman com uma matriz de 15 experimentos simultâneos, e analisados por tratamento estatístico proposto por Youden e Steiner. Finalmente, o método proposto pode ser também uma opção de êxito para a análise de cefazolina sódica, contribuindo para o controle de qualidade e para garantir a eficácia terapêutica.pt
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Farmacos e Médicamentos, Faculdade de Ciências Farmacêuticas de Araraquara, Araraquara, Rodovia Araraquara-Jaú, km1, Campus, CEP 14801-902, SP, Brasil
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Farmacos e Médicamentos, Faculdade de Ciências Farmacêuticas de Araraquara, Araraquara, Rodovia Araraquara-Jaú, km1, Campus, CEP 14801-902, SP, Brasil
dc.format.extent213-223
dc.identifierhttp://dx.doi.org/10.1590/S1984-82502011000100022
dc.identifier.citationBrazilian Journal of Pharmaceutical Sciences, v. 50, n. 1, p. 213-223, 2014.
dc.identifier.doi10.1590/S1984-82502011000100022
dc.identifier.fileISSN1984-8250-2014-50-01-213-223.pdf
dc.identifier.issn1984-8250
dc.identifier.lattes4238972287355427
dc.identifier.lattes9881720291571774
dc.identifier.scieloS1984-82502014000100022
dc.identifier.urihttp://hdl.handle.net/11449/133749
dc.language.isoeng
dc.relation.ispartofBrazilian Journal of Pharmaceutical Sciences
dc.relation.ispartofjcr0.483
dc.relation.ispartofsjr0,214
dc.rights.accessRightsAcesso abertopt
dc.sourceCurrículo Lattes
dc.subjectCefazolin sodium/determinationen
dc.subjectHigh performance liquid chromatography/reverse-phase/ quantitative analysisen
dc.subjectPharmaceutical industry/quality controlen
dc.subjectCefalosporine/quality controlen
dc.subjectMedicines/ quality controlen
dc.subjectCefazolina sódica/determinaçãopt
dc.subjectCromatografia líquida de alta eficiência/fase reversa/ análise quantitativapt
dc.subjectIndústria farmacêutica/controle de qualidadept
dc.subjectCefalosporina/controle de qualidadept
dc.subjectMedicamentos/controle de qualidadept
dc.titleValidation of analytical methodology for quantification of cefazolin sodium by liquid chromatographyen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublicatione214da1b-9929-4ae9-b8fd-655e9bfeda4b
relation.isDepartmentOfPublication.latestForDiscoverye214da1b-9929-4ae9-b8fd-655e9bfeda4b
relation.isOrgUnitOfPublication95697b0b-8977-4af6-88d5-c29c80b5ee92
relation.isOrgUnitOfPublication.latestForDiscovery95697b0b-8977-4af6-88d5-c29c80b5ee92
unesp.author.lattes4238972287355427
unesp.author.lattes9881720291571774
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências Farmacêuticas, Araraquarapt
unesp.departmentFármacos e Medicamentos - FCFpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
ISSN1984-8250-2014-50-01-213-223.pdf
Tamanho:
1.35 MB
Formato:
Adobe Portable Document Format