Publicação: Determination of Cd(II), Cu(II) and Ni(II) in aqueous samples by ICP-OES after on-line preconcentration in column packed with silica modified with 2-aminothiazole
dc.contributor.author | Castro, Gustavo R. [UNESP] | |
dc.contributor.author | Cristante, Valtair M. [UNESP] | |
dc.contributor.author | Padilha, Cilene C. F. [UNESP] | |
dc.contributor.author | Jorge, Sonia M. A. [UNESP] | |
dc.contributor.author | Florentino, Ariovaldo O. [UNESP] | |
dc.contributor.author | Prado, Alexandre G. S. | |
dc.contributor.author | Padilha, Pedro M. [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade de Brasília (UnB) | |
dc.date.accessioned | 2014-05-20T13:49:29Z | |
dc.date.available | 2014-05-20T13:49:29Z | |
dc.date.issued | 2008-01-01 | |
dc.description.abstract | This work describes the synthesis and characterization of 2-aminothiazole modified silica gel (SiAT) and the studies of adsorption and pre-concentration (in batch and using a flow-injection system coupled with optical emission spectrometer) of Cd(II), Cu(II) and Ni(II) in aqueous medium. The adsorption capacity for each metal ions in mmolg(-1) was: Cu(II) = 1.18, Ni(II) = 1.15 and Cd(II) = 1.10. The results obtained in the flow experiments showed about 100% of recovering of the metal ions adsorbed in a mini-column packed with 100 mg of SiAT, using 100 mu L of 2.0 mol L-1 HCl solution as eluent. The quantitative sorption-desorption of the metal ions made possible the application of a flow-injection system in the pre-concentration and quantification by ICP-OES of metal ions at trace level in natural water samples. | en |
dc.description.affiliation | UNESP, Dept Quim & Bioquim, IB, BR-18618000 Botucatu, SP, Brazil | |
dc.description.affiliation | UNESP, Dept Quim & Analit, Araraquara, SP, Brazil | |
dc.description.affiliation | UNESP, Dept Fis & Biofis, IB, Botucatu, SP, Brazil | |
dc.description.affiliation | UnB, Dept Quim Inorg, IQ, Brasilia, DF, Brazil | |
dc.description.affiliationUnesp | UNESP, Dept Quim & Bioquim, IB, BR-18618000 Botucatu, SP, Brazil | |
dc.description.affiliationUnesp | UNESP, Dept Quim & Analit, Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | UNESP, Dept Fis & Biofis, IB, Botucatu, SP, Brazil | |
dc.format.extent | 203-209 | |
dc.identifier | http://dx.doi.org/10.1007/s00604-007-0845-5 | |
dc.identifier.citation | Microchimica Acta. Wien: Springer Wien, v. 160, n. 1-2, p. 203-209, 2008. | |
dc.identifier.doi | 10.1007/s00604-007-0845-5 | |
dc.identifier.issn | 0026-3672 | |
dc.identifier.lattes | 6981448637456391 | |
dc.identifier.orcid | 0000-0003-4179-0574 | |
dc.identifier.uri | http://hdl.handle.net/11449/17643 | |
dc.identifier.wos | WOS:000252484600020 | |
dc.language.iso | eng | |
dc.publisher | Springer Wien | |
dc.relation.ispartof | Microchimica Acta | |
dc.relation.ispartofjcr | 5.705 | |
dc.relation.ispartofsjr | 1,240 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | pre-concentration | en |
dc.subject | 2-aminothiazole | en |
dc.subject | flow-injection system | en |
dc.subject | sol-gel method | en |
dc.subject | ICP-OES | en |
dc.title | Determination of Cd(II), Cu(II) and Ni(II) in aqueous samples by ICP-OES after on-line preconcentration in column packed with silica modified with 2-aminothiazole | en |
dc.type | Artigo | |
dcterms.license | http://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0 | |
dcterms.rightsHolder | Springer Wien | |
dspace.entity.type | Publication | |
unesp.author.lattes | 6981448637456391[7] | |
unesp.author.orcid | 0000-0003-4179-0574[7] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Biociências, Botucatu | pt |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Física e Biofísica - IBB | pt |
unesp.department | Química e Bioquímica - IBB | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: