Logotipo do repositório
 

Publicação:
Determination of Cd(II), Cu(II) and Ni(II) in aqueous samples by ICP-OES after on-line preconcentration in column packed with silica modified with 2-aminothiazole

dc.contributor.authorCastro, Gustavo R. [UNESP]
dc.contributor.authorCristante, Valtair M. [UNESP]
dc.contributor.authorPadilha, Cilene C. F. [UNESP]
dc.contributor.authorJorge, Sonia M. A. [UNESP]
dc.contributor.authorFlorentino, Ariovaldo O. [UNESP]
dc.contributor.authorPrado, Alexandre G. S.
dc.contributor.authorPadilha, Pedro M. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de Brasília (UnB)
dc.date.accessioned2014-05-20T13:49:29Z
dc.date.available2014-05-20T13:49:29Z
dc.date.issued2008-01-01
dc.description.abstractThis work describes the synthesis and characterization of 2-aminothiazole modified silica gel (SiAT) and the studies of adsorption and pre-concentration (in batch and using a flow-injection system coupled with optical emission spectrometer) of Cd(II), Cu(II) and Ni(II) in aqueous medium. The adsorption capacity for each metal ions in mmolg(-1) was: Cu(II) = 1.18, Ni(II) = 1.15 and Cd(II) = 1.10. The results obtained in the flow experiments showed about 100% of recovering of the metal ions adsorbed in a mini-column packed with 100 mg of SiAT, using 100 mu L of 2.0 mol L-1 HCl solution as eluent. The quantitative sorption-desorption of the metal ions made possible the application of a flow-injection system in the pre-concentration and quantification by ICP-OES of metal ions at trace level in natural water samples.en
dc.description.affiliationUNESP, Dept Quim & Bioquim, IB, BR-18618000 Botucatu, SP, Brazil
dc.description.affiliationUNESP, Dept Quim & Analit, Araraquara, SP, Brazil
dc.description.affiliationUNESP, Dept Fis & Biofis, IB, Botucatu, SP, Brazil
dc.description.affiliationUnB, Dept Quim Inorg, IQ, Brasilia, DF, Brazil
dc.description.affiliationUnespUNESP, Dept Quim & Bioquim, IB, BR-18618000 Botucatu, SP, Brazil
dc.description.affiliationUnespUNESP, Dept Quim & Analit, Araraquara, SP, Brazil
dc.description.affiliationUnespUNESP, Dept Fis & Biofis, IB, Botucatu, SP, Brazil
dc.format.extent203-209
dc.identifierhttp://dx.doi.org/10.1007/s00604-007-0845-5
dc.identifier.citationMicrochimica Acta. Wien: Springer Wien, v. 160, n. 1-2, p. 203-209, 2008.
dc.identifier.doi10.1007/s00604-007-0845-5
dc.identifier.issn0026-3672
dc.identifier.lattes6981448637456391
dc.identifier.orcid0000-0003-4179-0574
dc.identifier.urihttp://hdl.handle.net/11449/17643
dc.identifier.wosWOS:000252484600020
dc.language.isoeng
dc.publisherSpringer Wien
dc.relation.ispartofMicrochimica Acta
dc.relation.ispartofjcr5.705
dc.relation.ispartofsjr1,240
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectpre-concentrationen
dc.subject2-aminothiazoleen
dc.subjectflow-injection systemen
dc.subjectsol-gel methoden
dc.subjectICP-OESen
dc.titleDetermination of Cd(II), Cu(II) and Ni(II) in aqueous samples by ICP-OES after on-line preconcentration in column packed with silica modified with 2-aminothiazoleen
dc.typeArtigo
dcterms.licensehttp://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0
dcterms.rightsHolderSpringer Wien
dspace.entity.typePublication
unesp.author.lattes6981448637456391[7]
unesp.author.orcid0000-0003-4179-0574[7]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Biociências, Botucatupt
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentFísica e Biofísica - IBBpt
unesp.departmentQuímica e Bioquímica - IBBpt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: