Logo do repositório
 

Determination of the force systems produced by different configurations of tear drop orthodontic loops

dc.contributor.authorThiesen, Guilherme
dc.contributor.authorShimizu, Roberto Hideo [UNESP]
dc.contributor.authordo Valle, Caio Vinicius Martins
dc.contributor.authordo Valle-Corotti, Karyna Martins
dc.contributor.authorPereira, Jefferson Ricardo
dc.contributor.authorConti, Paulo Cesar Rodrigues
dc.contributor.institutionUNISUL-SC and UNIASSELVI
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-27T11:30:30Z
dc.date.available2014-05-27T11:30:30Z
dc.date.issued2013-08-30
dc.description.abstractObjective: To determine the mechanical characteristics of teardrop loop with and without helix fabricated using different metal alloy compositions (stainless steel and beta-titanium), submitted to different intensities of bends preactivation (0° and 40°), and with different cross-sectional dimension of the wire used to build these loops (0.017 x 0.025-in and 0.019 x 0.025-in). Methods: Eighty loops used to close spaces were submitted to mechanical tests. The magnitudes of horizontal force, the moment/force ratio, and the load/deflection ratio produced by the specimens were quantified. Loops were submitted to a total activation of 5.0 mm and the values were registered for each 1.0 mm of activation. For statistic data analysis, a analysis of variance was performed and a Tukey's Multiple Comparison test was used as supplement, considering a 5% level of significance. Results: In general, teardrop loops with helix produced lower magnitudes of horizontal force and load/deflection ratio, and higher moment/force ratio than teardrop loops without helix. Among all analyzed variables, metal alloy composition presented greater influence in the horizontal force and in the load/deflection ratio. The moment/force ratio showed to be more influenced by the preactivation of loops for space closure. © 2013 Dental Press Journal of Orthodontics.en
dc.description.affiliationPUCRS Graduation and Post-graduation course in Orthodontics UNISUL-SC and UNIASSELVI
dc.description.affiliationUNESP-Araraquara Tuiuti University
dc.description.affiliationFOB-USP Leonardo da Vinci University
dc.description.affiliationFOB-USP UNICID
dc.description.affiliationFOB-USP UNISUL-SC
dc.description.affiliationProsthesis FOB-USP
dc.description.affiliationUnespUNESP-Araraquara Tuiuti University
dc.identifierhttp://dx.doi.org/10.1590/S2176-94512013000200007
dc.identifier.citationDental Press Journal of Orthodontics, v. 18, n. 2, 2013.
dc.identifier.doi10.1590/S2176-94512013000200007
dc.identifier.file2-s2.0-84882932748.pdf
dc.identifier.issn2176-9451
dc.identifier.issn2177-6709
dc.identifier.scieloS2176-94512013000200007
dc.identifier.scopus2-s2.0-84882932748
dc.identifier.urihttp://hdl.handle.net/11449/76367
dc.language.isoeng
dc.relation.ispartofDental Press Journal of Orthodontics
dc.relation.ispartofsjr0,489
dc.relation.ispartofsjr0,489
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectBiomechanics
dc.subjectOrthodontic space closure
dc.subjectOrthodontics
dc.subjectTooth extraction
dc.titleDetermination of the force systems produced by different configurations of tear drop orthodontic loopsen
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/dpjo/paboutj.htm
dspace.entity.typePublication

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-84882932748.pdf
Tamanho:
279.73 KB
Formato:
Adobe Portable Document Format

Coleções