Logotipo do repositório
 

Publicação:
Influence of Nd:YAG laser on intrapulpal temperature and bond strength of human dentin under simulated pulpal pressure

dc.contributor.authorSilva, T. M. [UNESP]
dc.contributor.authorGonçalves, L. L. [UNESP]
dc.contributor.authorFonseca, B. M. [UNESP]
dc.contributor.authorEsteves, S. R. M. S. [UNESP]
dc.contributor.authorBarcellos, D. C. [UNESP]
dc.contributor.authorDamião, A. J.
dc.contributor.authorGonçalves, S. E. P. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionAerospace Technical Center (CTA)
dc.date.accessioned2015-12-07T15:39:54Z
dc.date.available2015-12-07T15:39:54Z
dc.date.issued2015-10-28
dc.description.abstractThe aim of this study was to evaluate the effects of simulated pulpal pressure (SPP) on the variation of intrapulpal temperature (ΔT) and microtensile bond strength (μTBS) to dentin submitted to an adhesive technique using laser irradiation. One hundred sound human molars were randomly divided into two groups (n = 50), according to the presence or absence of SPP (15 cm H2O). Each group was divided into five subgroups (n = 10) according to Nd:YAG laser energy (60, 80, 100, 120, 140 mJ/pulse). The samples were sequentially treated with the following: 37 % phosphoric acid, adhesive (Scotchbond Universal), irradiation with Nd:YAG laser (60 s), and light curing (10 s). ΔT was evaluated during laser irradiation using a type K thermocouple. Next, a composite resin block was build up onto the irradiated area. After 48 h, samples were submitted to microtensile test (10 kgf load cell, 0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey tests (p = 0.05). ANOVA revealed significant differences for ΔT and TBS in the presence of SPP. For ΔT, the highest mean (14.3 ± 3.23 °C)(A) was observed in 140 mJ and without SPP. For μTBS, the highest mean (33.4 ± 4.15 MPa)(A) was observed in 140 mJ and without SPP. SPP significantly reduced both ΔT and μTBS during adhesive procedures, lower laser energy parameters resulted in smaller ΔT, and the laser parameters did not influence the μTBS values.en
dc.description.affiliationOptical Surface Measurements Labs, Institute for Advanced Studies (IEAv), Aerospace Technical Center (CTA), Trevo Coronel Aviador José Alberto Albano do Amarante, 01, Putim, São José dos Campos, SP, Brazil.
dc.description.affiliationUnespDepartment of Restorative Dentistry, Institute of Science and Technology of São José dos Campos, UNESP—Univ Estadual Paulista, Avenida Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, SP CEP: 12245-000, Brazil.
dc.format.extent1-8
dc.identifierhttp://dx.doi.org/10.1007/s10103-015-1827-1
dc.identifier.citationLasers In Medical Science, p. 1-8, 2015.
dc.identifier.doi10.1007/s10103-015-1827-1
dc.identifier.issn1435-604X
dc.identifier.pubmed26510575
dc.identifier.urihttp://hdl.handle.net/11449/131668
dc.language.isoeng
dc.publisherSpringer
dc.relation.ispartofLasers In Medical Science
dc.rights.accessRightsAcesso restrito
dc.sourcePubMed
dc.subjectAdhesionen
dc.subjectIntrapulpal pressureen
dc.subjectNd:yag laseren
dc.subjectTemperatureen
dc.titleInfluence of Nd:YAG laser on intrapulpal temperature and bond strength of human dentin under simulated pulpal pressureen
dc.typeArtigo
dcterms.rightsHolderSpringer
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentOdontologia Restauradora - ICTpt

Arquivos