Logo do repositório
 

Patient comfort in periapical examination using digital receptors

dc.contributor.authorGonçalves, Andréa [UNESP]
dc.contributor.authorWiezel, V. G.
dc.contributor.authorGonçalves, Marcelo [UNESP]
dc.contributor.authorHebling, Josimeri [UNESP]
dc.contributor.authorSannomiya, E. K.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionSão Paulo Metodista Univ
dc.date.accessioned2013-09-30T18:32:00Z
dc.date.accessioned2014-05-20T13:44:50Z
dc.date.available2013-09-30T18:32:00Z
dc.date.available2014-05-20T13:44:50Z
dc.date.issued2009-10-01
dc.description.abstractObjectives: The aim of this study was to compare digital and conventional radiography with regard to patient comfort during periapical radiographic examination.Methods: 300 patients were submitted to a simulation of a radiographic periapical examination of a dentate region using conventional intraoral radiographic film (Kodak Insight) with and without the use of an RINK film holder, a Schick charge-coupled device (CCD) sensor, a Visualix CCD sensor and a Denoptix phosphor plate. The patients were asked to score how they felt in terms of comfort on a 100 mm visual analogue scale. The Wilcoxon test (alpha = 0.05) was applied to compare the comfort score of different types of imaging receptor from each simulated radiographic region reported by the patients.Results: The median of the comfort data according to the type of imaging receptor was 40 mm for conventional intraoral radiographic film with the use of the film holder, 85 mm for conventional intraoral radiographic film without the film holder, 80 mm for Schick and Visualix receptors, and 90 mm for the Denoptix receptor.Conclusions: Denoptix was the most comfortable imaging receptor, followed in decreasing order by Schick and Visualix, conventional intraoral radiographic film without using the film holder and conventional intraoral radiographic film with a film holder. Dentomaxillofacial Radiology (2009) 38, 484-488. doi: 10.1259/dmfr/82025587en
dc.description.affiliationSão Paulo State Univ, FOAr, UNESP, Dept Oral Diag & Surg,Araraquara Dent Sch, BR-14801903 Araraquara, SP, Brazil
dc.description.affiliationSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Orthodont & Pediat Dent, BR-14801903 Araraquara, SP, Brazil
dc.description.affiliationSão Paulo Metodista Univ, Sch Dent, Dept DentoMaxilloFacial Radiol, Sao Bernardo do Campo, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, FOAr, UNESP, Dept Oral Diag & Surg,Araraquara Dent Sch, BR-14801903 Araraquara, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Araraquara Dent Sch, UNESP, Dept Orthodont & Pediat Dent, BR-14801903 Araraquara, SP, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 05/02389-6
dc.description.sponsorshipIdFAPESP: 99/03026-1
dc.format.extent484-488
dc.identifierhttp://dx.doi.org/10.1259/dmfr/82025587
dc.identifier.citationDentomaxillofacial Radiology. London: British Inst Radiology, v. 38, n. 7, p. 484-488, 2009.
dc.identifier.doi10.1259/dmfr/82025587
dc.identifier.issn0250-832X
dc.identifier.lattes3373230215078349
dc.identifier.lattes1067437159861527
dc.identifier.urihttp://hdl.handle.net/11449/15725
dc.identifier.wosWOS:000270856600010
dc.language.isoeng
dc.publisherBritish Inst Radiology
dc.relation.ispartofDentomaxillofacial Radiology
dc.relation.ispartofjcr1.848
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectradiography, dental, digitalen
dc.subjectradiography, dentalen
dc.subjectpatient satisfactionen
dc.subjectpatient acceptance of health careen
dc.subjectpatient careen
dc.titlePatient comfort in periapical examination using digital receptorsen
dc.typeArtigopt
dcterms.licensehttp://www.birjournals.org/site/policy/licence.xhtml
dcterms.rightsHolderBritish Inst Radiology
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes3373230215078349[1]
unesp.author.lattes1067437159861527
unesp.author.orcid0000-0001-8498-8199[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentClínica Infantil - FOARpt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: