Logotipo do repositório
 

Publicação:
Evaluation of the load system produced by a single intrusion bend in a maxillary lateral incisor bracket with different alloys

dc.contributor.authorShintcovsk, Ricardo Lima
dc.contributor.authorSilva Junior, Roberto Soares da [UNESP]
dc.contributor.authorWhite, Larry
dc.contributor.authorMartins, Lidia Parsekian [UNESP]
dc.contributor.authorMartins, Renato Parsekian [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-11-26T17:55:00Z
dc.date.available2018-11-26T17:55:00Z
dc.date.issued2018-09-01
dc.description.abstractObjectives: To evaluate if a 0.5-mm vertical bend applied on an incisor bracket produces movements in other planes and if different wires influence these effects. Materials and Methods: An acrylic model of a treated patient with brackets passively bonded was attached to an Orthodontic Force Tester, and a load cell was attached to the left lateral incisor. Thirty 0.019 x 0.025-inch archwires were divided into three groups according to their alloy: SS (stainless steel), B-Ti (beta-titanium), and MF (beta-titanium wire coated with nickel-titanium). Step-bends of 0.5 mm high were placed on the lateral incisor bracket using a universal plier, and the forces and moments in three dimensions were statistically analyzed by analysis of variance and Tukey post hoc test. Results: SS produced a larger force (3.4 N) than the B-Ti (1.41 N) and the MF (0.53 N; P < .001). Lingual forces were produced by the SS (0.82 N) and B-Ti (0.31 N) groups, while in the MF group, the force was insignificant. SS produced a mesial force of 0.24 N, while the B-Ti force was insignificant and MF produced 0.09 N. Groups produced different crown-distal tipping moments (SS 31.48 N-mm, B-Ti 11.7 N-mm, and MF 4.55 N-mm) and different crown-buccal tipping moments. SS produced larger moments (3.63 N-mm) than B-Ti (1.02 N-mm) and MF (0.36 N-mm) wires. A mesial-out rotational moment was observed in all groups (SS = 7.17 N-mm, B-Ti = 3.46 N-mm, and MF = 0.86 N-mm). Conclusions: A 0.5-mm intrusion bend produced lingual and mesial side effects. In addition to the distal and buccal crown-tipping moments, there was a mesial-out moment. Compared with SS, B-Ti and MF wires produced lower forces. These more flexible wires showed side effects with lesser intensity.en
dc.description.affiliationUniv Estadual Paulista, Araraquara Sch Dent, Dept Orthodont, Araraquara, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Araraquara Sch Dent, Dept Orthodont, Araraquara, SP, Brazil
dc.format.extent611-616
dc.identifierhttp://dx.doi.org/10.2319/081717-556.1
dc.identifier.citationAngle Orthodontist. Newton N: E H Angle Education Research Foundation, Inc, v. 88, n. 5, p. 611-616, 2018.
dc.identifier.doi10.2319/081717-556.1
dc.identifier.issn0003-3219
dc.identifier.urihttp://hdl.handle.net/11449/164549
dc.identifier.wosWOS:000442353300013
dc.language.isoeng
dc.publisherE H Angle Education Research Foundation, Inc
dc.relation.ispartofAngle Orthodontist
dc.relation.ispartofsjr1,267
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectBends
dc.subjectIntrusion
dc.subjectMechanics
dc.titleEvaluation of the load system produced by a single intrusion bend in a maxillary lateral incisor bracket with different alloysen
dc.typeArtigopt
dcterms.rightsHolderE H Angle Education Research Foundation, Inc
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentClínica Infantil - FOARpt

Arquivos