Publicação: Evaluation of the load system produced by a single intrusion bend in a maxillary lateral incisor bracket with different alloys
dc.contributor.author | Shintcovsk, Ricardo Lima | |
dc.contributor.author | Silva Junior, Roberto Soares da [UNESP] | |
dc.contributor.author | White, Larry | |
dc.contributor.author | Martins, Lidia Parsekian [UNESP] | |
dc.contributor.author | Martins, Renato Parsekian [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2018-11-26T17:55:00Z | |
dc.date.available | 2018-11-26T17:55:00Z | |
dc.date.issued | 2018-09-01 | |
dc.description.abstract | Objectives: To evaluate if a 0.5-mm vertical bend applied on an incisor bracket produces movements in other planes and if different wires influence these effects. Materials and Methods: An acrylic model of a treated patient with brackets passively bonded was attached to an Orthodontic Force Tester, and a load cell was attached to the left lateral incisor. Thirty 0.019 x 0.025-inch archwires were divided into three groups according to their alloy: SS (stainless steel), B-Ti (beta-titanium), and MF (beta-titanium wire coated with nickel-titanium). Step-bends of 0.5 mm high were placed on the lateral incisor bracket using a universal plier, and the forces and moments in three dimensions were statistically analyzed by analysis of variance and Tukey post hoc test. Results: SS produced a larger force (3.4 N) than the B-Ti (1.41 N) and the MF (0.53 N; P < .001). Lingual forces were produced by the SS (0.82 N) and B-Ti (0.31 N) groups, while in the MF group, the force was insignificant. SS produced a mesial force of 0.24 N, while the B-Ti force was insignificant and MF produced 0.09 N. Groups produced different crown-distal tipping moments (SS 31.48 N-mm, B-Ti 11.7 N-mm, and MF 4.55 N-mm) and different crown-buccal tipping moments. SS produced larger moments (3.63 N-mm) than B-Ti (1.02 N-mm) and MF (0.36 N-mm) wires. A mesial-out rotational moment was observed in all groups (SS = 7.17 N-mm, B-Ti = 3.46 N-mm, and MF = 0.86 N-mm). Conclusions: A 0.5-mm intrusion bend produced lingual and mesial side effects. In addition to the distal and buccal crown-tipping moments, there was a mesial-out moment. Compared with SS, B-Ti and MF wires produced lower forces. These more flexible wires showed side effects with lesser intensity. | en |
dc.description.affiliation | Univ Estadual Paulista, Araraquara Sch Dent, Dept Orthodont, Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Araraquara Sch Dent, Dept Orthodont, Araraquara, SP, Brazil | |
dc.format.extent | 611-616 | |
dc.identifier | http://dx.doi.org/10.2319/081717-556.1 | |
dc.identifier.citation | Angle Orthodontist. Newton N: E H Angle Education Research Foundation, Inc, v. 88, n. 5, p. 611-616, 2018. | |
dc.identifier.doi | 10.2319/081717-556.1 | |
dc.identifier.issn | 0003-3219 | |
dc.identifier.uri | http://hdl.handle.net/11449/164549 | |
dc.identifier.wos | WOS:000442353300013 | |
dc.language.iso | eng | |
dc.publisher | E H Angle Education Research Foundation, Inc | |
dc.relation.ispartof | Angle Orthodontist | |
dc.relation.ispartofsjr | 1,267 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Web of Science | |
dc.subject | Bends | |
dc.subject | Intrusion | |
dc.subject | Mechanics | |
dc.title | Evaluation of the load system produced by a single intrusion bend in a maxillary lateral incisor bracket with different alloys | en |
dc.type | Artigo | pt |
dcterms.rightsHolder | E H Angle Education Research Foundation, Inc | |
dspace.entity.type | Publication | |
relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
relation.isOrgUnitOfPublication.latestForDiscovery | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Clínica Infantil - FOAR | pt |