Logo do repositório
 

Análise comparativa do ambiente de aviários de postura com diferentes sistemas de acondicionamento

dc.contributor.authorVitorasso, Guilherme [UNESP]
dc.contributor.authorPereira, Danilo Florentino [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:24:02Z
dc.date.available2014-05-27T11:24:02Z
dc.date.issued2009-11-01
dc.description.abstractPoulty house typology and the materials used (mainly for roofing) are the determining factors for an appropriate thermal condition aiming at production. In this context, the main point of this paper was to identify differences in the internal environment of two poultry houses, using monitoring and afterwards using statistics for comparing the environmental variables. The data analyzed did not show evidence of better thermal comfort for the house which was covered with ceramic roofing tile, because this house did not have ridged vents, making the hot air exit from the house difficult by the chimney effect. The ammonia concentration measured inside both houses was within the comfort limit. The temperature and humidity index of the house covered with ceramic roofing tiles was higher than the house which was covered with cement asbestos roofing tile, even though lower temperature on the tiles' surfaces was verified, showing the positive effects of the use of ridge vents at the housing. Based on the results obtained it is recommended for the Bastos, SP region, that poulty houses should be built with the ridge vent and long eaves beyond the roof of ceramic tiles.en
dc.description.affiliationUNESP, Av. Domingos da Costa Lopes, 780, CEP 17603-630, Tupã, SP
dc.description.affiliationUnespUNESP, Av. Domingos da Costa Lopes, 780, CEP 17603-630, Tupã, SP
dc.format.extent788-794
dc.identifierhttp://dx.doi.org/10.1590/S1415-43662009000600018
dc.identifier.citationRevista Brasileira de Engenharia Agricola e Ambiental, v. 13, n. 6, p. 788-794, 2009.
dc.identifier.doi10.1590/S1415-43662009000600018
dc.identifier.file2-s2.0-70350707715.pdf
dc.identifier.issn1415-4366
dc.identifier.issn1807-1929
dc.identifier.scieloS1415-43662009000600018
dc.identifier.scopus2-s2.0-70350707715
dc.identifier.urihttp://hdl.handle.net/11449/71224
dc.language.isopor
dc.relation.ispartofRevista Brasileira de Engenharia Agrícola e Ambiental
dc.relation.ispartofjcr0.619
dc.relation.ispartofsjr0,541
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectAnimal environment
dc.subjectRoof types
dc.subjectThermal comfort
dc.subjectAnimalia
dc.titleAnálise comparativa do ambiente de aviários de postura com diferentes sistemas de acondicionamentopt
dc.title.alternativeComparative analysis of the environment of poultry sheds with different systems of acclimatizationen
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/rbeaa/paboutj.htm#a04
dspace.entity.typePublication
unesp.author.orcid0000-0003-4602-8837[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências e Engenharia, Tupãpt
unesp.departmentAdministração - Tupãpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-70350707715.pdf
Tamanho:
137.68 KB
Formato:
Adobe Portable Document Format