Logotipo do repositório
 

Publicação:
Tribo-mechanical properties and cellular viability of electrochemically treated Ti-10Nb and Ti-20Nb alloys

dc.contributor.authorLuz, Aline R.
dc.contributor.authorLima, Gabriel G. de
dc.contributor.authorSantos Jr, Emanuel
dc.contributor.authorPereira, Bruno L.
dc.contributor.authorSato, Hebert Hiroshi
dc.contributor.authorLepienski, Carlos M.
dc.contributor.authorLima, Daniel B.
dc.contributor.authorLaurindo, Carlos
dc.contributor.authorGrandini, Carlos R. [UNESP]
dc.contributor.authorKuromoto, Neide K.
dc.contributor.institutionUniv Fed Parana
dc.contributor.institutionAthlone Inst Technol
dc.contributor.institutionCtr Univ Volta Redonda UniFOA
dc.contributor.institutionUniv Tecnol Fed Parana
dc.contributor.institutionUniv Fed Campina Grande
dc.contributor.institutionPontificia Univ Catolica Parana
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2019-10-04T12:34:53Z
dc.date.available2019-10-04T12:34:53Z
dc.date.issued2019-03-30
dc.description.abstractA number of researches have been concerned about the development of beta-type titanium alloys because they can present good biocompatibility, non-cytotoxicity, suitable mechanical and corrosion resistance behavior. However, due to their chemical inertness property, the surfaces of the novel Ti alloys must be modified by different methods to improve their bioactivity. This work is focused on the electrochemical surface modification of Ti-10Nb and Ti-20Nb alloys by Plasma Electrolytic Oxidation (PEO) method in 1.0 M H3PO4 electrolyte at 250 V. X-Ray diffraction showed that both binary Ti-Nb alloys are mainly composed of (alpha+beta) phase. The PEO treatment led to producing rough and thick titanium and niobium oxides films on the Ti-Nb alloys. The oxide films produced on the Ti-10Nb alloys have the anatase structure, whereas those formed on the Ti-20Nb alloy have an amorphous structure observed by Raman Spectroscopy. Hardness and elastic modulus were measured by instrumented indentation. Both oxide films are harder than their substrates (4.0-6.0 GPa) and have reduced elastic modulus values (100-110 GPa) compared to cp-Ti (reference). Linear reciprocating tests were employed to study the surface wear resistance of the samples. Among the non-treated samples, the Ti-10Nb alloy presented a better wear performance. In addition, the titanium and niobium oxides films formed on the Ti-10Nb alloy presented the most resistant surfaces. In relation to the cellular viability evaluation, the oxide films produced on both Ti-Nb alloys did not show any sign of cytotoxicity. Indeed, the porosity, roughness and chemical composition of the resulting titanium and niobium oxides films were able to promote osteoblast cells attachment and proliferation on their surfaces. Based on these findings, the PEO electrochemical treatment on Ti-10Nb alloy can form porous oxides coating and could be used as a reference line for manufacturing more wear resistant and non-cytotoxic surfaces to biomedical applications. (C) 2018 Elsevier B.V. All rights reserved.en
dc.description.affiliationUniv Fed Parana, Programa Posgrad Engn Ciencia Mat PIPE, Curitiba, Parana, Brazil
dc.description.affiliationAthlone Inst Technol, Mat Res Inst, Athlone, Ireland
dc.description.affiliationCtr Univ Volta Redonda UniFOA, Volta Redonda, RJ, Brazil
dc.description.affiliationUniv Fed Parana, Programa Posgrad Engn Mecan, BR-81531990 Curitiba, Parana, Brazil
dc.description.affiliationUniv Tecnol Fed Parana, Programa Posgrad Engn Mecan & Mat, Curitiba, Parana, Brazil
dc.description.affiliationUniv Fed Campina Grande, Dept Engn Mat, Campina Grande, PB, Brazil
dc.description.affiliationPontificia Univ Catolica Parana, Escola Politen, Dept Engn Mecan, Curitiba, Parana, Brazil
dc.description.affiliationUniv Estadual Paulista, Dept Fis, Campus Bauru, BR-17033360 Bauru, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Fis, Campus Bauru, BR-17033360 Bauru, SP, Brazil
dc.description.sponsorshipFundacao Araucaria
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipIdFundacao Araucaria: 685/2014
dc.description.sponsorshipIdFundacao Araucaria: 42466
dc.description.sponsorshipIdCNPq: 307037/2014-2
dc.description.sponsorshipIdCAPES: 1522225
dc.format.extent129-139
dc.identifierhttp://dx.doi.org/10.1016/j.jallcom.2018.11.192
dc.identifier.citationJournal Of Alloys And Compounds. Lausanne: Elsevier Science Sa, v. 779, p. 129-139, 2019.
dc.identifier.doi10.1016/j.jallcom.2018.11.192
dc.identifier.issn0925-8388
dc.identifier.urihttp://hdl.handle.net/11449/185371
dc.identifier.wosWOS:000457154700017
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofJournal Of Alloys And Compounds
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectTitanium alloys
dc.subjectOxidation
dc.subjectCoatings
dc.subjectCytotoxicity tests
dc.subjectMechanical properties
dc.subjectWear
dc.titleTribo-mechanical properties and cellular viability of electrochemically treated Ti-10Nb and Ti-20Nb alloysen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.lattes2949983867418338[9]
unesp.author.orcid0000-0002-3336-309X[9]
unesp.departmentFísica - FCpt

Arquivos