Logotipo do repositório
 

Publicação:
Ex vivo and in vivo study of Kowa HA-2 applanation tonometer in the measurement of intraocular pressure in dogs

dc.contributor.authorAndrade, Silvia Franco
dc.contributor.authorDe Andrade, Alexandre Lima [UNESP]
dc.contributor.authorKanashiro, Glaucia Prada
dc.contributor.authorSilva, Danielle Alves
dc.contributor.authorBarbero, Rafael Cabral
dc.contributor.authorKuhn, Jacqueline Marcussi Pereira
dc.contributor.authorDa Silva, Andressa Caroline
dc.contributor.institutionUNOESTE
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:02:40Z
dc.date.available2018-12-11T17:02:40Z
dc.date.issued2016-03-01
dc.description.abstractThe objective of this study was to evaluate the use of the Kowa HA-2 applanation tonometer in measuring intraocular pressure (IOP) in dogs. Twenty eyes were used in an ex vivo study in which the calibration curve for manometry vs. tonometry was determined by artificially raising the IOP in 5 mmHg increments up to 60 mmHg (10-60 mmHg). Both eyes of 10 anesthetized dogs were studied in vivo to compare manometry vs. tonometry. In the ambulatory study, 168 healthy eyes, 74 eyes with glaucoma and 60 eyes with uveitis were evaluated by tonometry, which was performed with topical anesthesia and 1% fluorescein eye drops for the formation of fluorescein semicircles. The ex vivo study showed an excellent correlation coefficient (r2= 0.993) between the aneroid manometer and the Kowa HA-2 tonometer. In the in vivo study, there was no significant difference (P>0.05) between the IOP values by manometry and tonometry, showing the excellent accuracy of the Kowa HA-2 tonometer. In the ambulatory study using the Kowa HA-2 tonometer, the IOP values (mean±SD, in mmHg) were 15.1±1.8 (12.0 - 20.0) for the healthy eyes, 25.2±4.0 (20.0 - 38.0) for glaucomatous eyes and 10.1±2.3 (5.0 - 13.7) for eyes with uveitis. There was a strong correlation between the IOP values obtained by direct ocular manometry and those from the Kowa HA-2 tonometer. In the ambulatory study, the IOP values measured by the tonometer were compatible for healthy eyes and for eyes with glaucoma or uveitis. We conclude that Kowa HA-2 applanation tonometer is accurate and practical for IOP measurement in dogs.en
dc.description.affiliationDepartamento de Clínica Médica de Pequenos Animais Curso de Medicina Veterinária Universidade Do Oeste Paulista UNOESTE
dc.description.affiliationDepartamento de Clínica Cirurgia e Reprodução Animal Faculdade de Medicina Veterinária FMVA UNESP
dc.description.affiliationDepartamento de Anestesiologia Curso de Medicina Veterinária UNOESTE
dc.description.affiliationCurso de Medicina Veterinária UNOESTE
dc.description.affiliationUnespDepartamento de Clínica Cirurgia e Reprodução Animal Faculdade de Medicina Veterinária FMVA UNESP
dc.format.extent797-806
dc.identifierhttp://dx.doi.org/10.5433/1679-0359.2016v37n2p797
dc.identifier.citationSemina:Ciencias Agrarias, v. 37, n. 2, p. 797-806, 2016.
dc.identifier.doi10.5433/1679-0359.2016v37n2p797
dc.identifier.issn1679-0359
dc.identifier.issn1676-546X
dc.identifier.scopus2-s2.0-84964994909
dc.identifier.urihttp://hdl.handle.net/11449/172911
dc.language.isoeng
dc.relation.ispartofSemina:Ciencias Agrarias
dc.relation.ispartofsjr0,320
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.subjectApplanation tonometer
dc.subjectDogs
dc.subjectGlaucoma
dc.subjectKowa HA-2 tonometer
dc.subjectOcular manometry
dc.subjectUveitis
dc.titleEx vivo and in vivo study of Kowa HA-2 applanation tonometer in the measurement of intraocular pressure in dogsen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes6404176495306171[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina Veterinária, Araçatubapt
unesp.departmentClínica, Cirurgia e Reprodução Animal - FMVApt

Arquivos