Publicação: A complete dosimetric characterization of two Sr-90-Y-90 dermatologic applicators
dc.contributor.author | Coelho, T. S. | |
dc.contributor.author | Fernandes, Marco Antônio Rodrigues [UNESP] | |
dc.contributor.author | Yoriyaz, H. | |
dc.contributor.author | Antonio, P. L. | |
dc.contributor.institution | Instituto de Pesquisas Energéticas e Nucleares (IPEN) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T13:34:04Z | |
dc.date.available | 2014-05-20T13:34:04Z | |
dc.date.issued | 2011-03-11 | |
dc.description.abstract | A complete dosimetric characterization of two Amershan Sr-90-Y-90 dermatologic applicators is described in this present work. The dosimetric parameters analyzed are: percentage depth dose curve, radial dose distribution, non-uniformity and asymmetry. Both applicators are planar-circular having 22.57 and 9.0 mm diameters. In the range where the percentage depth dose goes from 100% down to 20%, the measured percentage depth dose and that obtained by the Monte Carlo simulation have shown maximum discrepancy of 5.3% for both applicators. The radial dose distribution has been measured at several depths using a GafChromic (R) EBT QD+ films and it was also calculated by simulation. The discrepancies found did not exceed 5.9% up to the depth of 1.8 mm, where the percentage depth dose drops to 40% of the maximum. The maximum non-uniformity and asymmetry are 1.7% and 5.3% for the first applicator and 22.7% and 25.9% for the second applicator, respectively. Both applicators meet the specification for the maximum non-uniformity established by the adopted protocol, whose limit is 30%. As for the asymmetry the limit is 20% and the second applicator exceeded it in about 5.9%. (C) 2010 Elsevier B.V. All rights reserved. | en |
dc.description.affiliation | IPEN CNEN SP, São Paulo, Brazil | |
dc.description.affiliation | Univ Estadual Paulista, Fac Med Botucatu, Dept Dermatol & Radioterapia, São Paulo, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Fac Med Botucatu, Dept Dermatol & Radioterapia, São Paulo, Brazil | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.format.extent | 147-151 | |
dc.identifier | http://dx.doi.org/10.1016/j.nima.2010.12.179 | |
dc.identifier.citation | Nuclear Instruments & Methods In Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment. Amsterdam: Elsevier B.V., v. 632, n. 1, p. 147-151, 2011. | |
dc.identifier.doi | 10.1016/j.nima.2010.12.179 | |
dc.identifier.issn | 0168-9002 | |
dc.identifier.lattes | 2307939425313065 | |
dc.identifier.uri | http://hdl.handle.net/11449/11661 | |
dc.identifier.wos | WOS:000288049000022 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | Nuclear Instruments & Methods In Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment | |
dc.relation.ispartofjcr | 1.336 | |
dc.relation.ispartofsjr | 0,814 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Betatherapy | en |
dc.subject | Monte Carlo method | en |
dc.subject | Keloids | en |
dc.subject | Pterygium | en |
dc.subject | Dosimetry | en |
dc.title | A complete dosimetric characterization of two Sr-90-Y-90 dermatologic applicators | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. | |
dspace.entity.type | Publication | |
unesp.author.lattes | 2307939425313065 | |
unesp.author.orcid | 0000-0003-4023-236X[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatu | pt |
unesp.department | Dermatologia e Radioterapia - FMB | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: