Logotipo do repositório
 

Publicação:
The effect of adhesive and flowable composite on postoperative sensitivity: 2-Week results

dc.contributor.authorPerdigão, Jorge
dc.contributor.authorAnauate-Netto, Camillo
dc.contributor.authorCarmo, André R. P.
dc.contributor.authorHodges, James S.
dc.contributor.authorCordeiro, Hiram J. D.
dc.contributor.authorLewgoy, Hugo R.
dc.contributor.authorDutra-Corrêa, Maristela
dc.contributor.authorCastilhos, Natália
dc.contributor.authorAmore, Ricardo [UNESP]
dc.contributor.institutionUniversidade de Mogi das Cruzes (UMC)
dc.contributor.institutionUniversidade Bandeirante de São Paulo (UNIBAN)
dc.contributor.institutionUniversidade Cruzeiro do Sul
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversity of Minnesota
dc.date.accessioned2014-05-27T11:21:11Z
dc.date.available2014-05-27T11:21:11Z
dc.date.issued2004-11-01
dc.description.abstractObjective: To measure 2-week postoperative sensitivity in Class II composite restorations placed with a self-etching adhesive (Clearfil SE Bond) or a total-etch adhesive (Prime&Bond NT) with or without a flowable composite as cervical increment. Method and materials: Upon approval by the University of Guarulhos Committee on Human Subjects, 100 restorations were inserted in 46 patients who required Class II restorations in their molars and premolars. Enamel and dentin walls were conditioned with a self-etching primer (for Clearfil SE Bond) or etched with 34% phosphoric acid (for Prime&Bond NT). A 1- to 2-mm-thick increment of a flowable composite (Filtek Flow) was used in the proximal box in 50% of the restorations of each adhesive. Preparations were restored with a packable composite (Surefil). The restorations were evaluated preoperatively and 2 weeks postoperatively for sensitivity to cold, air, and masticatory forces using a visual analog scale. Marginal integrity of the accessible margins was also evaluated. Statistical analysis used a mixed linear model with subject as a random effect. Results: Ninety-eight teeth from 44 subjects were observed at 2 weeks. The type of adhesive and use of flowable composite had no significant effects or interaction for any of the four outcomes of interest, ie, change from baseline to 2 weeks in sensitivity and response time for the cold or air stimulus. For the air stimulus, the overall average change from baseline was not significant for either sensitivity or response time. For the cold stimulus, the overall average change from baseline was significant for both sensitivity and response time. No case of sensitivity to masticatory forces was observed. Conclusion: No differences in postoperative sensitivity were observed between a self-etch adhesive and a total-etch adhesive at 2 weeks. The use of flowable composite did not decrease postoperative sensitivity.en
dc.description.affiliationDivision of Operative Dentistry Department of Restorative Sciences University of Minnesota, Minneapolis, MN
dc.description.affiliationDepartment of Operative Dentistry University of Mogi Das Cruzes (UMC), Mogi das Cruzes, SP
dc.description.affiliationDepartment of Operative Dentistry UMC, Mogi das Cruzes, SP
dc.description.affiliationDivision of Biostatistics School of Dentistry University of Minnesota, Minneapolis, MN
dc.description.affiliationBiostatistical Core School of Dentistry University of Minnesota, Minneapolis, MN
dc.description.affiliationDepartment of Operative Dentistry Univ. de Bandeirante de S. Paulo, São Paulo, SP
dc.description.affiliationUniversidade Cruzeiro do Sul, São Paulo, SP
dc.description.affiliationUniv. Estadual de São Paulo, São José dos Campos, SP
dc.description.affiliationDepartment of Operative Dentistry UNIBAN, São Paulo, SP
dc.description.affiliationUNESP, São José dos Campos, SP
dc.description.affiliationUniversity of Minnesota Division of Operative Dentistry Department of Restorative Sciences, 515 SE Delaware St, Minneapolis, MN 55455
dc.description.affiliationUnespUNESP, São José dos Campos, SP
dc.format.extent777-784
dc.identifierhttp://www.quintpub.com/journals/qi/abstract.php?iss2_id=386&article_id=4823
dc.identifier.citationQuintessence International, v. 35, n. 10, p. 777-784, 2004.
dc.identifier.issn0033-6572
dc.identifier.scopus2-s2.0-4944221152
dc.identifier.urihttp://hdl.handle.net/11449/67942
dc.identifier.wosWOS:000225359900002
dc.language.isoeng
dc.relation.ispartofQuintessence International
dc.relation.ispartofjcr1.088
dc.relation.ispartofsjr0,563
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.subjectClinical trial
dc.subjectDental bonding
dc.subjectResin composite
dc.subjectphosphoric acid
dc.subjecttissue adhesive
dc.subjectadult
dc.subjectair
dc.subjectclinical article
dc.subjectcold sensitivity
dc.subjectcomposite material
dc.subjectcontrolled study
dc.subjectdental caries
dc.subjectdentin
dc.subjectdentin sensitivity
dc.subjectenamel
dc.subjecthuman
dc.subjectmastication
dc.subjectmolar tooth
dc.subjectpostoperative period
dc.subjectpremolar tooth
dc.subjectresponse time
dc.subjectstatistical analysis
dc.subjectstatistical significance
dc.subjectuniversity
dc.subjectvisual analog scale
dc.subjectAcid Etching, Dental
dc.subjectAdult
dc.subjectComposite Resins
dc.subjectDental Cavity Preparation
dc.subjectDental Enamel
dc.subjectDental Restoration, Permanent
dc.subjectDentin
dc.subjectDentin Sensitivity
dc.subjectDentin-Bonding Agents
dc.subjectFollow-Up Studies
dc.subjectHumans
dc.subjectMarginal Adaptation (Dentistry)
dc.subjectMiddle Aged
dc.subjectPain Measurement
dc.subjectPhosphoric Acids
dc.subjectPolymethacrylic Acids
dc.subjectResin Cements
dc.titleThe effect of adhesive and flowable composite on postoperative sensitivity: 2-Week resultsen
dc.typeArtigopt
dcterms.licensehttp://www.quintpub.com/terms.php
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt

Arquivos