Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2025 a 4 de janeiro de 2026.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

Logo do repositório

Optimal restoration of active distribution systems with voltage control and closed-loop operation

dc.contributor.authorVargas, Renzo
dc.contributor.authorMacedo, Leonardo H.
dc.contributor.authorHome-Ortiz, Juan M.
dc.contributor.authorMantovani, José Roberto Sanches
dc.contributor.authorRomero, Rubén
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2021-02-22T17:21:45Z
dc.date.available2021-02-22T17:21:45Z
dc.date.issued2021-01-11
dc.description.abstractThis paper presents a new mixed-integer second-order cone programming model for solving the restoration problem in active distribution systems considering the optimal control of distributed generators (DGs), voltage regulators (VRs), on-load tap changers (OLTCs), and capacitor banks (CBs). In contrast to most of the works found in the literature, temporary loops may be formed in the network during the restorative operation state. This operating condition allows restoring the service to more loads. In this way, the objective function of the problem minimizes (i) the total load not supplied, (ii) the number of switching operations, (iii) the changes in the statuses of the voltage control devices and in the dispatch of the DGs, and (iv) the number of basic loops formed in the system. Several tests are carried out using a 53-node system for single-fault and multiple-fault scenarios. The results obtained with the proposed approach outperform the solutions achieved when only radial configurations are allowed in the problem. Moreover, it is also verified that the voltage control allows for more efficient restoration schemes.pt
dc.description.affiliationUniversidade Estadual Paulista
dc.description.affiliationUFABC - Universidade Federal do ABC
dc.description.sponsorshipIdCAPES: 001
dc.description.sponsorshipIdCNPq: 305852/2017-5
dc.description.sponsorshipIdCNPq: 305318/2016-0
dc.description.sponsorshipIdFAPESP: 2015/21972-6
dc.description.sponsorshipIdFAPESP: 2018/20355-1
dc.description.sponsorshipIdFAPESP: 2019/19632-3
dc.description.sponsorshipIdFAPESP: 2019/01841-5
dc.description.sponsorshipIdFAPESP: 2019/23755-3
dc.description.sponsorshipIdENEL: APLPEE-00390-1062/2017 - P&D-00390-1083-2020_UFABC
dc.description.versionPostprintpt
dc.identifier.doi10.1109/TSG.2021.3050931
dc.identifier.issn1949-3053
dc.identifier.lattes0410725069211275
dc.identifier.lattes2040962189153040
dc.identifier.lattes4332331001576336
dc.identifier.lattes0614021283361265
dc.identifier.lattes7303300747184265
dc.identifier.orcid0000-0003-2287-1571
dc.identifier.orcid0000-0001-9178-0601
dc.identifier.orcid0000-0002-0746-8082
dc.identifier.orcid0000-0002-7149-6184
dc.identifier.orcid0000-0002-7744-254X
dc.identifier.urihttp://hdl.handle.net/11449/202755
dc.language.isoeng
dc.publisherIEEE
dc.relation.ispartofIEEE Transactions on Smart Gridpt
dc.rights.accessRightsAcesso aberto
dc.subjectDistributed generationpt
dc.subjectDistribution systems restorationpt
dc.subjectMixed-integer second-order cone programmingpt
dc.subjectTemporary closed-loop operationpt
dc.subjectVoltage-dependent modelspt
dc.titleOptimal restoration of active distribution systems with voltage control and closed-loop operationpt
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteirapt
unesp.departmentEngenharia Elétrica - FEISpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
vargas_r_postprint_ilha_optimal.pdf
Tamanho:
1.34 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
2.26 KB
Formato:
Item-specific license agreed upon to submission
Descrição: