Publicação: Preload Evaluation of Different Screws in External Hexagon Joint
dc.contributor.author | Assunção, Wirley Goncalves [UNESP] | |
dc.contributor.author | Delben, Juliana Aparecida [UNESP] | |
dc.contributor.author | Tabata, Lucas Fernando | |
dc.contributor.author | Barao, Valentim Adelino Ricardo [UNESP] | |
dc.contributor.author | Gomes, Erica Alves | |
dc.contributor.author | Garcia, Idelmo Rangel [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade de Brasília (UnB) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2013-09-30T18:29:59Z | |
dc.date.accessioned | 2014-05-20T13:43:40Z | |
dc.date.available | 2013-09-30T18:29:59Z | |
dc.date.available | 2014-05-20T13:43:40Z | |
dc.date.issued | 2012-02-01 | |
dc.description.abstract | Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns.Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05).Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05).Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50) | en |
dc.description.affiliation | Univ Estadual Paulista UNESP, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, São Paulo, Brazil | |
dc.description.affiliation | São Paulo State Univ, Dept Dent Mat & Prosthodon, São Paulo, Brazil | |
dc.description.affiliation | Universidade de Brasilia (UnB) UnB, Sch Dent, Brasilia, DF, Brazil | |
dc.description.affiliation | Univ São Paulo, Dept Dent Mat & Prosthodon, Ribeirao Preto Dent Sch, São Paulo, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista UNESP, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, São Paulo, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, Dept Dent Mat & Prosthodon, São Paulo, Brazil | |
dc.format.extent | 46-50 | |
dc.identifier | http://dx.doi.org/10.1097/ID.0b013e31823fcbce | |
dc.identifier.citation | Implant Dentistry. Philadelphia: Lippincott Williams & Wilkins, v. 21, n. 1, p. 46-50, 2012. | |
dc.identifier.doi | 10.1097/ID.0b013e31823fcbce | |
dc.identifier.issn | 1056-6163 | |
dc.identifier.lattes | 4438747643373395 | |
dc.identifier.uri | http://hdl.handle.net/11449/15250 | |
dc.identifier.wos | WOS:000299348200011 | |
dc.language.iso | eng | |
dc.publisher | Lippincott Williams & Wilkins | |
dc.relation.ispartof | Implant Dentistry | |
dc.relation.ispartofjcr | 1.307 | |
dc.relation.ispartofsjr | 0,712 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Web of Science | |
dc.subject | dental implants | en |
dc.subject | implant-supported dental prosthesis | en |
dc.subject | prosthesis failure | en |
dc.subject | torque | en |
dc.title | Preload Evaluation of Different Screws in External Hexagon Joint | en |
dc.type | Artigo | pt |
dcterms.license | http://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf | |
dcterms.rightsHolder | Lippincott Williams & Wilkins | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 4438747643373395 | |
unesp.author.orcid | 0000-0002-8903-0737[1] | |
unesp.author.orcid | 0000-0002-6391-9917[4] | |
unesp.author.orcid | 0000-0002-6510-3727[2] | |
unesp.author.orcid | 0000-0003-1454-8360[5] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: