Logo do repositório
 

Influence of Different Base Thicknesses on Maxillary Complete Denture Processing: Linear and Angular Graphic Analysis on the Movement of Artificial Teeth

dc.contributor.authorMazaro, José Vitor Quinelli [UNESP]
dc.contributor.authorGennari Filho, Humberto [UNESP]
dc.contributor.authorVedovatto, Eduardo [UNESP]
dc.contributor.authorAmoroso, Andressa Paschoal [UNESP]
dc.contributor.authorPellizzer, Eduardo Piza [UNESP]
dc.contributor.authorZavanelli, Adriana Cristina [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:10Z
dc.date.accessioned2014-05-20T13:43:45Z
dc.date.available2013-09-30T18:30:10Z
dc.date.available2014-05-20T13:43:45Z
dc.date.issued2011-09-01
dc.description.abstractObjective: The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization.Methods: A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.50, and 3.75 mm and gypsum or silicone flask investment. Points were demarcated on the distal surface of the second molars and on the back of the gypsum cast at the alveolar ridge level to allow linear and angular measurement using AutoCAD software. The data were subjected to analysis of variance with double factor, Tukey test and Fisher (post hoc).Results: Angular analysis of the varying methods and their interactions generated a statistical difference (P = 0.023) when the magnitudes of molar inclination were compared. Tooth movement was greater for thin-based prostheses, 1.25 mm (-0.234), versus thick 3.75 mm (0.2395), with antagonistic behavior. Prosthesis investment with silicone (0.053) showed greater vertical change compared with the gypsum investment (0.032). There was a difference between the point of analysis, demonstrating that the changes were not symmetric.Conclusions: All groups evaluated showed change in the position of artificial teeth after processing. The complete denture with a thin base (1.25 mm) and silicone investment showed the worst results, whereas intermediate thickness (2.50 mm) was demonstrated to be ideal for the denture base.en
dc.description.affiliationUNSEP Univ Estadual Paulista, Sch Dent Aracatuba, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.description.affiliationUnespUNSEP Univ Estadual Paulista, Sch Dent Aracatuba, Dept Dent Mat & Prosthodont, São Paulo, Brazil
dc.format.extent1661-1665
dc.identifierhttp://dx.doi.org/10.1097/SCS.0b013e31822e5d8c
dc.identifier.citationJournal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 22, n. 5, p. 1661-1665, 2011.
dc.identifier.doi10.1097/SCS.0b013e31822e5d8c
dc.identifier.issn1049-2275
dc.identifier.lattes5335208171935802
dc.identifier.lattes5581364193525500
dc.identifier.lattes8942804819076392
dc.identifier.orcid0000-0003-1781-1953
dc.identifier.urihttp://hdl.handle.net/11449/15295
dc.identifier.wosWOS:000295398700026
dc.language.isoeng
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofJournal of Craniofacial Surgery
dc.relation.ispartofjcr0.772
dc.relation.ispartofsjr0,448
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectMaxillary complete dentureen
dc.subjectacrylic resinsen
dc.subjectmicrowaveen
dc.subjectsiliconeen
dc.subjectartificial toothen
dc.titleInfluence of Different Base Thicknesses on Maxillary Complete Denture Processing: Linear and Angular Graphic Analysis on the Movement of Artificial Teethen
dc.typeArtigopt
dcterms.licensehttp://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf
dcterms.rightsHolderLippincott Williams & Wilkins
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes5335208171935802
unesp.author.lattes5581364193525500
unesp.author.lattes8942804819076392[6]
unesp.author.orcid0000-0003-0670-5004[5]
unesp.author.orcid0000-0003-1781-1953[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: