Logotipo do repositório
 

Publicação:
Adaptação do PourThru para avaliação de substratos com diferentes granulometrias

dc.contributor.authorLudwig, Fernanda
dc.contributor.authorGuerrero, Amaralina Celoto
dc.contributor.authorFerreira, Guilherme Amaral
dc.contributor.authorFernandes, Dirceu Maximino [UNESP]
dc.contributor.authorBôas, Roberto Lyra Villas [UNESP]
dc.contributor.institutionUnidade em Santa Cruz do Sul
dc.contributor.institutionCentro de Ciências e Tecnologia Alimentar
dc.contributor.institutionCentro de Citricultura Sylvio Moreira - APTA
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:34:02Z
dc.date.available2018-12-11T17:34:02Z
dc.date.issued2017-01-01
dc.description.abstractPeriodic monitoring of the substrate solution allows the nutritional control of plants to be done more quickly and conveniently. In order to this monitoring become a routine among the producers of potted flowers, a standardization of non-destructive methods and easy application are required. This study was conducted in order to adapt of the PourThru methodology for substrate evaluation with different particle sizes. It was conducted on substrates with different particle sizes. Two tests were performed to define the amount of water to be applied, the time between irrigation and the collect of the leachate. Both tests were done using substrates with grain size 4-2 mm, 2-1 mm < 4 mm < 2 mm < 1 mm and four repetitions. For the test I, we used the factorial 5 × 4 (5 particle sizes and 4 volumes of water), with volumes of 50, 75, 100 and 125 mL. For test II, we used the 5 × 5 factorial (5 granulometry balance and 5 times), with times of 30, 60, 90, 120 and 150 minutes. The leach solution was evaluated for electrical conductivity and pH. The methodology presented showed constraints when the substrates had particle sizes between 4 and 2 mm, and less than 1 mm. The larger the particle sizes is, the greater is the formation of preferential channels that leads to the possibility of mixing the water used as carrier and the solution to be leached is. The smaller the particle size is, the greater is the tendency of adsorption of the nutrients by the particles. For the pine bark substrate and vase with 1.3 L, it is suggested 60 minutes as settling time and the application of 75 mL of water for leaching the displacement.en
dc.description.affiliationUniversidade Estadual do Rio Grande do Sul (UERGS) Unidade em Santa Cruz do Sul
dc.description.affiliationUniversidade Federal de Campina Grande (UFCG) Centro de Ciências e Tecnologia Alimentar
dc.description.affiliationCentro de Citricultura Sylvio Moreira - APTA
dc.description.affiliationUniversidade Estadual Paulista 'Júlio de Mesquita Filho' (UNESP) Departamento de Recursos Naturais/Ciência do Solo (FCA/UNESP)
dc.description.affiliationUnespUniversidade Estadual Paulista 'Júlio de Mesquita Filho' (UNESP) Departamento de Recursos Naturais/Ciência do Solo (FCA/UNESP)
dc.format.extent22-29
dc.identifierhttp://dx.doi.org/10.14295/oh.v23i1.911
dc.identifier.citationOrnamental Horticulture, v. 23, n. 1, p. 22-29, 2017.
dc.identifier.doi10.14295/oh.v23i1.911
dc.identifier.issn2447-536X
dc.identifier.scopus2-s2.0-85029213610
dc.identifier.urihttp://hdl.handle.net/11449/179162
dc.language.isopor
dc.relation.ispartofOrnamental Horticulture
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.subjectElectrical conductivity
dc.subjectGerbera jamesonii
dc.subjectLeached
dc.subjectpH
dc.titleAdaptação do PourThru para avaliação de substratos com diferentes granulometriaspt
dc.title.alternativeAdaptation of PourThru for evaluation of substrates with different granulometriesen
dc.typeArtigo
dspace.entity.typePublication
unesp.departmentSolos e Recursos Ambientais - FCApt

Arquivos