Publicação:
Standardization of platelet parameters determination in blood samples collected with EDTA

dc.contributor.authorSilveira, M. M. [UNESP]
dc.contributor.authorFonseca, Luiz Marcos da [UNESP]
dc.contributor.institutionUniversidade do Oeste Paulista (UNOESTE)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:21:00Z
dc.date.available2014-05-27T11:21:00Z
dc.date.issued2003-12-01
dc.description.abstractThe Abbott Cell-Dyn 3000 automated hematological analyzer prepares a histogram of platelet volume, which is measured by a technique using electrical impedance, inferring from its platelet count (PLT), mean platelet volume (MPV) and platelet distribution width (PDW). This equipment also calculates the plateletcrit (PCT). These platelet parameters may be important to evaluate platelet function, but they require standardization, because platelets swell when in contact with ethylenediaminetetra-acetic acid salts, hence an increase in blood sample storage time produces artificially increased results. To assess the effect of storage time on MPV, PLT, PDW and PCT, blood samples from 23 sickle cell anemia patients during steady state (Group I) and 50 from healthy controls (Group II) were placed in Vacutainer® tubes with dipotassium ethylenediaminetetra-acetic acid and measured over a period of 1440 minutes (24 h) at the following times: immediately after the venipuncture (time 0), 15, 30, 60, 120, 240, 360, 480 and 1440 minutes. The mean values of MPV and PCT were significantly increased (p<0.00001) along the storage time in both groups. The mean values of PLT and PDW were practically stable (p>0.05) throughout the storage time in both groups.en
dc.description.affiliationDepartamento de Analises Clinicas Faculdade de Farmacia e Bioquimica UNOESTE, Presidente Prudente - SP
dc.description.affiliationDepartamento de Analises Clinicas Faculdade de Ciencias Farmaceuticas UNESP, Araraquara - SP
dc.description.affiliationUnespDepartamento de Analises Clinicas Faculdade de Ciencias Farmaceuticas UNESP, Araraquara - SP
dc.format.extent71-78
dc.identifier.citationRevista de Ciencias Farmaceuticas, v. 24, n. 1, p. 71-78, 2003.
dc.identifier.issn0101-3793
dc.identifier.lattes4419635633356792
dc.identifier.scopus2-s2.0-4644256640
dc.identifier.urihttp://hdl.handle.net/11449/67583
dc.language.isoeng
dc.relation.ispartofRevista de Ciencias Farmaceuticas
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.subjectBlood sample storage time
dc.subjectEthylenediaminetetra- acetic acid
dc.subjectMean platelet volume
dc.subjectPlateletcrit
dc.subjectStandardization
dc.subjectblood analysis
dc.subjectblood sampling
dc.subjectblood storage
dc.subjectcell swelling
dc.subjectcontrolled study
dc.subjectdiagnostic value
dc.subjecthistogram
dc.subjecthuman
dc.subjecthuman cell
dc.subjectimpedance
dc.subjectmean platelet volume
dc.subjectplatelet distribution width
dc.subjectsickle cell anemia
dc.subjectstandardization
dc.subjectstorage time
dc.subjectthrombocyte
dc.subjectthrombocyte count
dc.subjectthrombocyte preservation
dc.subjectthrombocyte volume
dc.subjecttime
dc.subjectvein puncture
dc.titleStandardization of platelet parameters determination in blood samples collected with EDTAen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes4419635633356792
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências Farmacêuticas, Araraquarapt
unesp.departmentAnálises Clínicas - FCFpt

Arquivos