Logotipo do repositório
 

Publicação:
Response of L-alanine and 2-methylalanine minidosimeters for K-Band (24 GHz) EPR dosimetry

dc.contributor.authorChen, F.
dc.contributor.authorGraeff, Carlos Frederico de Oliveira [UNESP]
dc.contributor.authorBaffa, O.
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:23:00Z
dc.date.available2014-05-20T15:23:00Z
dc.date.issued2007-11-01
dc.description.abstractMinidosimeters of L-alanine and 2-methylalanine (2MA) were prepared and tested as potential candidates for small radiation field dosimetry. To quantify the free radicals created by radiation a K-Band (24 GHz) EPR spectrometer was used. X-rays provided by a 6 MV clinical linear accelerator were used to irradiate the minidosimeters in the dose range of 0.5-30 Gy. The dose-response curves for both radiation sensitive materials displayed a good linear behavior in the dose range indicated with 2MA being more radiation sensitive than L-alanine. Moreover, 2MA showed a smaller LLD (lower limit detection) value. The proposed system minidosimeter/K-Band spectrometer was able to detect 10 Gy EPR spectra with good signal-to-noise ratio (S/N). The overall uncertainty indicates that this system shows a good performance for the detection of dose values of 20 Gy and above, which are dose values typically used in radiosurgery treatments. (c) 2007 Elsevier B.V. All rights reserved.en
dc.description.affiliationUniv São Paulo, FFCLRP, Dept Math & Phys, BR-14040901 Ribeirao Preto, SP, Brazil
dc.description.affiliationState Univ São Paulo, FC, Dept Phys, BR-17033360 Bauru, Brazil
dc.description.affiliationUnespState Univ São Paulo, FC, Dept Phys, BR-17033360 Bauru, Brazil
dc.format.extent277-281
dc.identifierhttp://dx.doi.org/10.1016/j.nimb.2007.08.097
dc.identifier.citationNuclear Instruments & Methods In Physics Research Section B-beam Interactions With Materials and Atoms. Amsterdam: Elsevier B.V., v. 264, n. 2, p. 277-281, 2007.
dc.identifier.doi10.1016/j.nimb.2007.08.097
dc.identifier.issn0168-583X
dc.identifier.orcid0000-0003-0162-8273
dc.identifier.urihttp://hdl.handle.net/11449/33867
dc.identifier.wosWOS:000251873600011
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofNuclear Instruments & Methods In Physics Research Section B-beam Interactions With Materials and Atoms
dc.relation.ispartofjcr1.323
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectminidosimeterpt
dc.subjectL-alaninept
dc.subject2-methylalaninept
dc.subjectK-Band EPRpt
dc.subjectsmall field dosimetrypt
dc.titleResponse of L-alanine and 2-methylalanine minidosimeters for K-Band (24 GHz) EPR dosimetryen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.lattes5268607684223281[2]
unesp.author.orcid0000-0003-0162-8273[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências, Baurupt
unesp.departmentFísica - FCpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: