Logotipo do repositório
 

Publicação:
Evaluation of the physical and chemical properties of two commercial and three experimental root-end filling materials

dc.contributor.authorVivan, Rodrigo Ricci
dc.contributor.authorZapata, Ronald Ordinola
dc.contributor.authorZeferino, Marcia A.
dc.contributor.authorBramante, Clovis Monteiro
dc.contributor.authorBernardineli, Norberti
dc.contributor.authorGarcia, Roberto Brandao
dc.contributor.authorHungaro Duarte, Marco Antonio
dc.contributor.authorTanomaru Filho, Mario [UNESP]
dc.contributor.authorde Moraes, Ivaldo Gomes
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:47:03Z
dc.date.available2014-05-20T13:47:03Z
dc.date.issued2010-08-01
dc.description.abstractObjective. The aim of this study was to evaluate the pH, calcium release, setting time, and solubility of two commercially available mineral trioxide aggregate (MTA) cements (white MTA Angelus and MTA Bio), and of three experimental cements (light-cured MTA, Portland cement with 20% bismuth oxide and 5% calcium sulfate, and an epoxy resin-based cement).Study design. For evaluation of pH and calcium ion release, polyethylene tubes with 1.0 mm internal diameter and 10.0 mm length were filled with the cements and immediately immersed in flasks containing 10 mL deionized water. After 3, 24, 72, and 168 hours, the tubes were removed and the water from the previous container was measured for its pH and calcium content with a pH meter and an atomic absorption spectrophotometer. For analysis of the setting time, Gilmore needles weighing 100 g and 456.5 g were used, in accordance with the American Society for Testing and Materials specification no. C266-03. Solubility of each cement was also tested.Results. All the cements were alkaline and released calcium ions, with a declining trend over time. After 3 hours, Portland cement + bismuth oxide and MTA Bio had the highest pH and light-cured MTA the lowest. After 1 week, MTA Bio had the highest pH and light-cured MTA and epoxy resin-based cement the lowest. Regarding calcium ion release, after 3 hours, Portland cement + bismuth oxide showed the highest release. After 1 week, MTA Bio had the highest. Epoxy resin-based cement and light-cured MTA had the lowest calcium release in all evaluation periods. Regarding setting times, white MTA Angelus and MTA Bio had the shortest, Portland cement + bismuth oxide had an intermediate setting time, and the epoxy resin-based cement had the longest. The materials that showed the lowest solubility values were the epoxy resin-based cement, Portland cement + bismuth oxide, and light-cured MTA. The highest solubility values were presented in white MTA Angelus and MTA Bio.Conclusions. The white MTA Angelus and MTA Bio had the shortest setting times, higher pH and calcium ion release, and the highest solubility. In contrast, the epoxy resin-based cement and light-cured MTA showed lower values of solubility, pH, and calcium ion release. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 250-256)en
dc.description.affiliationUniv São Paulo, Dept Operat Dent Dent Mat & Endodont, Dent Sch Bauru, Bauru, SP, Brazil
dc.description.affiliationSagrado Coracao Univ, Dept Hlth Sci, Bauru, SP, Brazil
dc.description.affiliationSão Paulo State Univ, Dept Restorat Dent, Dent Sch Araraquara, Araraquara, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Dept Restorat Dent, Dent Sch Araraquara, Araraquara, SP, Brazil
dc.format.extent250-256
dc.identifierhttp://dx.doi.org/10.1016/j.tripleo.2010.04.021
dc.identifier.citationOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology. New York: Mosby-elsevier, v. 110, n. 2, p. 250-256, 2010.
dc.identifier.doi10.1016/j.tripleo.2010.04.021
dc.identifier.issn1079-2104
dc.identifier.lattes2665211298584751
dc.identifier.urihttp://hdl.handle.net/11449/16705
dc.identifier.wosWOS:000280333900018
dc.language.isoeng
dc.publisherMosby-elsevier
dc.relation.ispartofOral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titleEvaluation of the physical and chemical properties of two commercial and three experimental root-end filling materialsen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderMosby-elsevier
dspace.entity.typePublication
unesp.author.lattes2665211298584751
unesp.author.orcid0000-0003-3051-737X[7]
unesp.author.orcid0000-0002-2574-4706[8]
unesp.author.orcid0000-0001-9738-0828[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: