Publicação: Orthodontic brackets removal under shear and tensile bond strength resistance tests - a comparative test between light sources
dc.contributor.author | Silva, P. C. G. [UNESP] | |
dc.contributor.author | Porto-Neto, S. T. [UNESP] | |
dc.contributor.author | Lizarelli, R. | |
dc.contributor.author | Bagnato, V S | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2014-05-20T15:32:21Z | |
dc.date.available | 2014-05-20T15:32:21Z | |
dc.date.issued | 2008-01-01 | |
dc.description.abstract | We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased. | en |
dc.description.affiliation | Univ Estadual Paulista, Fac Odontol Araraquara, Araraquara, SP, Brazil | |
dc.description.affiliation | Univ São Paulo, Phys Inst São Carlos, BR-13560970 São Carlos, SP, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Fac Odontol Araraquara, Araraquara, SP, Brazil | |
dc.format.extent | 220-226 | |
dc.identifier | http://dx.doi.org/10.1002/lapl.200710103 | |
dc.identifier.citation | Laser Physics Letters. Weinheim: Wiley-v C H Verlag Gmbh, v. 5, n. 3, p. 220-226, 2008. | |
dc.identifier.doi | 10.1002/lapl.200710103 | |
dc.identifier.issn | 1612-2011 | |
dc.identifier.uri | http://hdl.handle.net/11449/41275 | |
dc.identifier.wos | WOS:000254163300012 | |
dc.language.iso | eng | |
dc.publisher | Wiley-v C H Verlag Gmbh | |
dc.relation.ispartof | Laser Physics Letters | |
dc.relation.ispartofjcr | 2.240 | |
dc.relation.ispartofsjr | 0,818 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Web of Science | |
dc.subject | lEDs | en |
dc.subject | bracket | en |
dc.subject | tensile | en |
dc.subject | shear | en |
dc.subject | bonding strength | en |
dc.subject | fracture patterns | en |
dc.title | Orthodontic brackets removal under shear and tensile bond strength resistance tests - a comparative test between light sources | en |
dc.type | Artigo | pt |
dcterms.license | http://iopscience.iop.org/info/page/openaccess | |
dcterms.rightsHolder | Wiley-v C H Verlag Gmbh | |
dspace.entity.type | Publication | |
relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
relation.isOrgUnitOfPublication.latestForDiscovery | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: