Logotipo do repositório
 

Publicação:
Effect of light-curing protocols on the mechanical behavior of bulk-fill resin composites

dc.contributor.authorBesegato, João Felipe
dc.contributor.authorJussiani, Eduardo Inocente
dc.contributor.authorAndrello, Avacir Casanova
dc.contributor.authorFernandes, Ricardo Vignoto
dc.contributor.authorSalomão, Fabio Martins [UNESP]
dc.contributor.authorVicentin, Bruno Luiz Santana
dc.contributor.authorDezan-Garbelini, Cássia Cilene
dc.contributor.authorHoeppner, Márcio Grama
dc.contributor.institutionUniversidade Estadual de Londrina (UEL)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2019-10-06T16:04:32Z
dc.date.available2019-10-06T16:04:32Z
dc.date.issued2019-02-01
dc.description.abstractObjective: To investigate the effect of two light-curing protocols on mechanical behavior of three bulk-fill resin composites (BFRC) considering their optical properties. Methods: One increment of 4 mm thickness of the bulk-fill resin composites Opus Bulk Fill, Tetric N-Ceram and Filtek Bulk Fill Flow were submitted to two different light-curing protocols: Sp - irradiance of 1000 mW/cm2 (20 s); Xp - irradiance of 3200 mW/cm2 (6 s). To assess the influence on the mechanical behavior it was studied polymerization shrinkage by X-ray microtomography (n = 3), Vickers hardness (n = 10) at the top and bottom surfaces of the samples, irradiance reaching the bottom surface (n = 3) and absorbance spectrum during the light-curing time interval (n = 3). Data were analyzed by two-way ANOVA test for parametric data and Kruskal Wallis test, followed by Wilcoxon or Mann-Whitney U post-test, for non-parametric data. Results: All BFRCs contracted when light-cured, with greater contraction for Xp. Filltek Bulk Fill Flow showed highest polymerization shrinkage, for both Sp and Xp. All BFRCs showed minor hardness values on the bottom surface, with greater reduction for Xp. All BFRCs exhibited a decrease in irradiance at 4 mm depth. A decrease in absorbance intensity throughout the light-cure was observed, except for Opus Bulk Fill. Conclusions: Regardless BFRCs composition, the light-curing protocol with lower irradiance and longer exposure time results in lower polymerization shrinkage and higher hardness. The higher irradiance in a shorter time interval compromises the mechanical behavior of the resin composites, which may result in undesirable clinical outcomes.en
dc.description.affiliationDepartment of Restorative Dentistry State University of Londrina – UEL, Rua Pernambuco 540
dc.description.affiliationDepartment of Physics State University of Londrina – UEL, Rodovia Celso Garcia Cid, Pr 445 Km 380
dc.description.affiliationDepartment of Restorative Dentistry Araçatuba Dental School São Paulo State University – UNESP, Rua José Bonifácio 1193
dc.description.affiliationDepartment of Oral Medicine and Pediatric Dentistry State University of Londrina – UEL, Rua Pernambuco 540
dc.description.affiliationUnespDepartment of Restorative Dentistry Araçatuba Dental School São Paulo State University – UNESP, Rua José Bonifácio 1193
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipIdCAPES: 001
dc.format.extent381-387
dc.identifierhttp://dx.doi.org/10.1016/j.jmbbm.2018.10.026
dc.identifier.citationJournal of the Mechanical Behavior of Biomedical Materials, v. 90, p. 381-387.
dc.identifier.doi10.1016/j.jmbbm.2018.10.026
dc.identifier.issn1878-0180
dc.identifier.issn1751-6161
dc.identifier.scopus2-s2.0-85056220054
dc.identifier.urihttp://hdl.handle.net/11449/188328
dc.language.isoeng
dc.relation.ispartofJournal of the Mechanical Behavior of Biomedical Materials
dc.rights.accessRightsAcesso abertopt
dc.sourceScopus
dc.subjectAbsorbance
dc.subjectComposite resins
dc.subjectDental materials
dc.subjectHardness
dc.subjectIrradiance
dc.subjectPhysical properties
dc.subjectPolymerization
dc.subjectX-ray microtomography
dc.titleEffect of light-curing protocols on the mechanical behavior of bulk-fill resin compositesen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentOdontologia Restauradora - FOApt

Arquivos