Logotipo do repositório
 

Publicação:
Straight and angulated abutments in platform switching: influence of loading on bone stress by three-dimensional finite element analysis

dc.contributor.authorMartini, Ana Paula
dc.contributor.authorFreitas Júnior, Amilcar
dc.contributor.authorAlmeida, Erika
dc.contributor.authorRocha, Eduardo Passos [UNESP]
dc.contributor.authorAnchieta, Rodolfo Bruniera
dc.contributor.authorKina, Sidney
dc.contributor.authorFasolo, Guilherme Bortolon
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2016-01-28T16:54:27Z
dc.date.available2016-01-28T16:54:27Z
dc.date.issued2012
dc.description.abstractPURPOSE: In view of reports in the literature on the benefits achieved with the use of platform switching, described as the use of an implant with a larger diameter than the abutment diameter, the goal being to prevent the (previously) normal bone loss down to the first thread that occurs around most implants, thus enhancing soft tissue aesthetics and stability and the need for implant inclination due to bone anatomy in some cases, the aim of this study was to evaluate bone stress distribution on peri-implant bone, by using three-dimensional finite element analysis to simulate the influence of implants with different abutment angulations (0 and 15 degrees) in platform switching. METHODS: Four mathematical models of an implant-supported central incisor were created with varying abutment angulations: straight abutment (S1 and S2) and angulated abutment at 15 degrees (A1 and A2), submitted to 2 loading conditions (100 N): S1 and A1-oblique loading (45 degrees) and S2 and A2-axial loading, parallel to the long axis of the implant. Maximum (σmax) and minimum (σmin) principal stress values were obtained for cortical and trabecular bone. RESULTS: Models S1 and A1 showed higher σmax in cortical and trabecular bone when compared with S2 and A2. The highest σmax values (in MPa) in the cortical bone were found in S1 (28.5), followed by A1 (25.7), S2 (11.6), and A2 (5.15). For the trabecular bone, the highest σmax values were found in S1 (7.53), followed by A1 (2.87), S2 (2.85), and A2 (1.47). CONCLUSIONS: Implants with straight abutments generated the highest stress values in bone. In addition, this effect was potentiated when the load was applied obliquely.en
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Materiais Odontológicos e Prótese, Faculdade de Odontologia de Araçatuba, Araçatuba, Rua José Bonifácio, 1193, Vl Mendonça, CEP 16015050, SP, Brasil
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Materiais Odontológicos e Prótese, Faculdade de Odontologia de Araçatuba, Araçatuba, Rua José Bonifácio, 1193, Vl Mendonça, CEP 16015050, SP, Brasil
dc.format.extent415-418
dc.identifierhttp://dx.doi.org/10.1097/SCS.0b013e31824b9c17
dc.identifier.citationThe Journal of Craniofacial Surgery, v. 23, n. 02, p. 415-418, 2012.
dc.identifier.doi10.1097/SCS.0b013e31824b9c17
dc.identifier.issn1049-2275
dc.identifier.lattes3383392287039820
dc.identifier.urihttp://hdl.handle.net/11449/133288
dc.language.isoeng
dc.relation.ispartofThe Journal of Craniofacial Surgery
dc.relation.ispartofjcr0.772
dc.relation.ispartofsjr0,448
dc.rights.accessRightsAcesso restritopt
dc.sourceCurrículo Lattes
dc.titleStraight and angulated abutments in platform switching: influence of loading on bone stress by three-dimensional finite element analysisen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes3383392287039820
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais Odontológicos e Prótesept

Arquivos