Logotipo do repositório
 

Publicação:
Fractal dimension of the mandibular trabecular bone measured on digital and digitized images.

dc.contributor.authorOliveira, Matheus Lima de
dc.contributor.authorSaraiva, Juliana Alcaras
dc.contributor.authorScaf, Gulnara
dc.contributor.authorLoffredo, Leonor de Castro Monteiro [UNESP]
dc.contributor.authorTosoni, Guilherme Monteiro [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-08-06T16:12:45Z
dc.date.available2015-08-06T16:12:45Z
dc.date.issued2015
dc.description.abstractAims: This study compared fractal dimension (FD) values on mandibular trabecular bone in digital and digitized images at different spatial and contrast resolutions. Materials and Methods: 12 radiographs of dried human mandibles were obtained using custom-fabricated hybrid image receptors composed of a periapical radiographic film and a photostimulable phosphor plate (PSP). The film/ PSP sets were disassembled, and the PSPs produced images with 600 dots per inch (dpi) and 16 bits. These images were exported as tagged image file format (TIFF), 16 and 8 bits, and 600, 300 and 150 dpi. The films were processed and digitized 3 times on a flatbed scanner, producing TIFF images with 600, 300 and 150 dpi, and 8 bits. On each image, a circular region of interest was selected on the trabecular alveolar bone, away from root apices and FD was calculated by tile counting method. Two-way ANOVA and Tukey’s test were conducted to compare the mean values of FD, according to image type and spatial resolution (α = 5%). Results: Spatial resolution was directly and inversely proportional to FD mean values and standard deviation, respectively. Spatial resolution of 150 dpi yielded significant lower mean values of FD than the resolutions of 600 and 300 dpi ( P < 0.05). A nonsignificant variability was observed for the image types ( P > 0.05). The interaction between type of image and level of spatial resolution was not signi fi cant (P > 0.05). Conclusion: Under the tested, conditions, FD values of the mandibular trabecular bone assessed either by digital or digitized images did not change. Furthermore, these values were in fluenced by lower spatial resolution but not by contrast resolution.en
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Diagnóstico e Cirurgia, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680, Centro, CEP 14801903, SP, Brasil
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Diagnóstico e Cirurgia, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680, Centro, CEP 14801903, SP, Brasil
dc.format.extent39-43
dc.identifier.citationJournal of Oral and Maxillofacial Radiology, v. 3, n. 2, p. 39-43, 2015.
dc.identifier.doi10.4103/2321-3841.157519
dc.identifier.issn2321-3841
dc.identifier.lattes9312677491239162
dc.identifier.lattes3156969817236677
dc.identifier.lattes0692567697594977
dc.identifier.lattes5663622442588861
dc.identifier.urihttp://hdl.handle.net/11449/125662
dc.language.isoeng
dc.relation.ispartofJournal of Oral and Maxillofacial Radiology
dc.rights.accessRightsAcesso restritopt
dc.sourceCurrículo Lattes
dc.subjectDigital dental radiographyen
dc.subjectfractalsen
dc.subjectmandibleen
dc.subjectX-rayen
dc.subjectfilmen
dc.titleFractal dimension of the mandibular trabecular bone measured on digital and digitized images.en
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes9312677491239162
unesp.author.lattes3156969817236677
unesp.author.lattes0692567697594977
unesp.author.lattes5663622442588861
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentDiagnóstico e Cirurgia - FOARpt

Arquivos