Logotipo do repositório
 

Publicação:
Statistical methods for assessing agreement between double readings of clinical measurements

dc.contributor.authorVieira, Sonia
dc.contributor.authorCorrente, Jose Eduardo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionSao Leopoldo Mandic Dent Res Ctr
dc.date.accessioned2014-05-20T13:48:02Z
dc.date.available2014-05-20T13:48:02Z
dc.date.issued2011-09-01
dc.description.abstractStatistical analysis of data is crucial in cephalometric investigations. There are certainly excellent examples of good statistical practice in the field, but some articles published worldwide have carried out inappropriate analyses. Objective: The purpose of this study was to show that when the double records of each patient are traced on the same occasion, a control chart for differences between readings needs to be drawn, and limits of agreement and coefficients of repeatability must be calculated. Material and methods: Data from a well-known paper in Orthodontics were used for showing common statistical practices in cephalometric investigations and for proposing a new technique of analysis. Results: A scatter plot of the two radiograph readings and the two model readings with the respective regression lines are shown. Also, a control chart for the mean of the differences between radiograph readings was obtained and a coefficient of repeatability was calculated. Conclusions: A standard error assuming that mean differences are zero, which is referred to in Orthodontics and Facial Orthopedics as the Dahlberg error, can be calculated only for estimating precision if accuracy is already proven. When double readings are collected, limits of agreement and coefficients of repeatability must be calculated. A graph with differences of readings should be presented and outliers discussed.en
dc.description.affiliationState Univ São Paulo UNESP, Inst Biosci, Dept Biostat, Botucatu, SP, Brazil
dc.description.affiliationSao Leopoldo Mandic Dent Res Ctr, Campinas, SP, Brazil
dc.description.affiliationUnespState Univ São Paulo UNESP, Inst Biosci, Dept Biostat, Botucatu, SP, Brazil
dc.format.extent488-492
dc.identifierhttp://dx.doi.org/10.1590/S1678-77572011000500009
dc.identifier.citationJournal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 19, n. 5, p. 488-492, 2011.
dc.identifier.fileS1678-77572011000500009.pdf
dc.identifier.issn1678-7757
dc.identifier.orcid0000-0001-5478-4996
dc.identifier.scieloS1678-77572011000500009
dc.identifier.urihttp://hdl.handle.net/11449/17123
dc.identifier.wosWOS:000299004400009
dc.language.isoeng
dc.publisherUniversidade de São Paulo (USP), Faculdade de Odontologia de Bauru
dc.relation.ispartofJournal of Applied Oral Science
dc.relation.ispartofjcr1.709
dc.relation.ispartofsjr0,645
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectMeasurementsen
dc.subjectOrthodonticsen
dc.subjectErrorsen
dc.titleStatistical methods for assessing agreement between double readings of clinical measurementsen
dc.typeArtigo
dcterms.licensehttp://www.scielo.br/revistas/jaos/paboutj.htm
dcterms.rightsHolderUniv São Paulo Fac Odontologia Bauru
dspace.entity.typePublication
unesp.author.orcid0000-0001-5478-4996[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Biociências, Botucatupt
unesp.departmentBioestatística - IBBpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1678-77572011000500009.pdf
Tamanho:
1.19 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: