Logotipo do repositório
 

Publicação:
Effect of cleanser solutions on the retention force of O’Ring attachment: An in vitro study

dc.contributor.authorFelipucci, Daniela Nair Borges
dc.contributor.authorCurylofo, Patricia Almeida
dc.contributor.authorCrizóstomo, Luciana Costa
dc.contributor.authorVaz, Luis Geraldo [UNESP]
dc.contributor.authorAlves, Suleima Do Vale
dc.contributor.authorMacedo, Ana Paula
dc.contributor.authorPagnano, Valéria Oliveira
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2021-06-25T11:07:34Z
dc.date.available2021-06-25T11:07:34Z
dc.date.issued2020-11-01
dc.description.abstractThe aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized water (DW) was used as a control. Matrices containing two implants and abutments and acrylic specimens with the metal capsules were obtained and divided into the groups. A simulation of 90 overnight immersions (8 h) was performed, and the tensile strength value was obtained at the beginning (T0) and in every 30 days (T1, T2 and T3) (n=6). In order to analyze o-ring surface damage after the immersions, a scanning electron microscopy (SEM) was used (n=1). For statistical analysis of the results, analysis of variance (ANOVA) and multiple comparisons with Bonferroni adjustment (test power=1.000; α=0.05) were used. There was a significant difference for the factors time (p<0.001), solution (p<0.001) and for the interaction time × solution (p<0.001). Considering the times of each solution, only for DW there was no significant loss of retention over time. Comparing the solutions in each moment, there was no difference among the solutions in T0. From T1, CF and SH provided less retention than DW (p<0.005). Through SEM it was possible to observe changes in the surface of the CF and SH nitrile o-rings. CF and SH should be avoided due to deleterious action in o-rings.en
dc.description.affiliationRibeirão Preto School of Dentistry USP-Universidade de São Paulo
dc.description.affiliationAraraquara School of Dentistry UNESP-Universidade Estadual Paulista
dc.description.affiliationUnespAraraquara School of Dentistry UNESP-Universidade Estadual Paulista
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 2011/20830-2
dc.format.extent657-663
dc.identifierhttp://dx.doi.org/10.1590/0103-6440202003268
dc.identifier.citationBrazilian Dental Journal, v. 31, n. 6, p. 657-663, 2020.
dc.identifier.doi10.1590/0103-6440202003268
dc.identifier.fileS0103-64402020000600657.pdf
dc.identifier.issn1806-4760
dc.identifier.issn0103-6440
dc.identifier.scieloS0103-64402020000600657
dc.identifier.scopus2-s2.0-85096432585
dc.identifier.urihttp://hdl.handle.net/11449/208167
dc.language.isoeng
dc.relation.ispartofBrazilian Dental Journal
dc.rights.accessRightsAcesso abertopt
dc.sourceScopus
dc.subjectDenture cleanser
dc.subjectOverdenture
dc.subjectRetention
dc.subjectScanning electronic microscopy
dc.titleEffect of cleanser solutions on the retention force of O’Ring attachment: An in vitro studyen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0103-64402020000600657.pdf
Tamanho:
343.97 KB
Formato:
Adobe Portable Document Format