Publicação: Pulpal temperature increases with Er : YAG laser and high-speed handpieces
dc.contributor.author | Cavalcanti, B. N. | |
dc.contributor.author | Lage-Marques, J. L. | |
dc.contributor.author | Rode, S. M. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.contributor.institution | Ibirapuera Univ | |
dc.date.accessioned | 2014-05-20T15:22:01Z | |
dc.date.available | 2014-05-20T15:22:01Z | |
dc.date.issued | 2003-11-01 | |
dc.description.abstract | Statement of problem. During tooth preparation, both high-speed handpieces and lasers generate heat, which, if not controlled, can cause pulpal necrosis.Purpose. The aim of this study was to compare temperature increases produced by a high-speed dental handpiece with those produced by a relatively new instrument, the Er:YAG (erbium: yttrium-aluminum-garnet) laser.Material and methods. Thirty bovine mandibular incisors were reduced to an enamel/dentin thickness of 2.5 mm. Class V preparations were completed to a depth of 2.0 mm, measured with a caliper or by a mark oil the burs. A thermocouple was placed inside the pulp chamber to determine temperature increases (degreesC). Analysis was performed on the following groups (n = 10): Group 1, high-speed handpiece without water cooling, Group 11, high-speed handpiece with water cooling (30 mL/min), and Group III, the noncontact Er:YAG laser (2.94 mum at 350 mJ/10 Hz) with water cooling (4.5 mL/min). The temperature increases were recorded by a computer linked to the thermocouples. The data were analyzed using the Kruskal-Wallis test. The Dunn multiple comparison test was used as post hoc test (alpha = .05).Results. The average temperature rises were: 11.64degreesC (+/-4.35) for Group 1, 0.96degreesC (+/-0.71) for Group 11, and 2.69degreesC (+/-1.12) for Group III. There were no statistical differences between Groups 11 and III, both 11 and III differed from Group I significantly (P = .000 and P = .002, respectively).Conclusion. The preparations made with the high-speed and the laser instrument generated similar heat increases under water cooling. Water cooling was essential to avoid destructive temperature increases when using both the high-speed handpiece and laser. | en |
dc.description.affiliation | São Paulo State Univ, Sch Dent, Dept Dent Mat & Prosthet, São Paulo, Brazil | |
dc.description.affiliation | Univ São Paulo, Dept Operat Dent, São Paulo, Brazil | |
dc.description.affiliation | Ibirapuera Univ, São Paulo, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, Sch Dent, Dept Dent Mat & Prosthet, São Paulo, Brazil | |
dc.format.extent | 447-451 | |
dc.identifier | http://dx.doi.org/10.1016/j.prosdent.2003.08.022 | |
dc.identifier.citation | Journal of Prosthetic Dentistry. St Louis: Mosby, Inc., v. 90, n. 5, p. 447-451, 2003. | |
dc.identifier.doi | 10.1016/j.prosdent.2003.08.022 | |
dc.identifier.issn | 0022-3913 | |
dc.identifier.lattes | 9633326235160414 | |
dc.identifier.lattes | 3422118958429909 | |
dc.identifier.uri | http://hdl.handle.net/11449/33080 | |
dc.identifier.wos | WOS:000186476900007 | |
dc.language.iso | eng | |
dc.publisher | Mosby, Inc | |
dc.relation.ispartof | Journal of Prosthetic Dentistry | |
dc.relation.ispartofjcr | 2.347 | |
dc.relation.ispartofsjr | 1,087 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.title | Pulpal temperature increases with Er : YAG laser and high-speed handpieces | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Mosby, Inc | |
dspace.entity.type | Publication | |
unesp.author.lattes | 9633326235160414 | |
unesp.author.lattes | 3422118958429909 | |
unesp.author.orcid | 0000-0002-4261-4217[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Materiais Odontológicos e Prótese - ICT | pt |
unesp.department | Odontologia Restauradora - ICT | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: