Logotipo do repositório
 

Publicação:
Passivity Versus Unilateral Angular Misfit: Evaluation of Stress Distribution on Implant-Supported Single Crowns: Three-Dimensional Finite Element Analysis

dc.contributor.authorGomes, Erica Alves [UNESP]
dc.contributor.authorAssunção, Wirley Goncalves [UNESP]
dc.contributor.authorRicardo Barao, Valentim Adelino [UNESP]
dc.contributor.authorDelben, Juliana Aparecida [UNESP]
dc.contributor.authorRocha, Eduardo Passos [UNESP]
dc.contributor.authorSousa, Edson Antonio Capello [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:10:32Z
dc.date.accessioned2014-05-20T13:43:32Z
dc.date.available2013-09-30T18:10:32Z
dc.date.available2014-05-20T13:43:32Z
dc.date.issued2010-11-01
dc.description.abstractThe aim of this study was to evaluate the effect of unilateral angular misfit of 100 Km on stress distribution of implant-supported single crowns with ceramic veneering and gold framework by three-dimensional finite element analysis. Two three-dimensional models representing a maxillary section of premolar region were constructed: group 1 (control)-crown completely adapted to the implant and group 2-crown with unilateral angular misfit of 100 Km. A vertical force of 100 N was applied on 2 centric points of the crown. The von Mises stress was used as an analysis criterion. The stress values and distribution in the main maps (204.4 MPa for group 1 and 205.0 MPa for group 2) and in the other structures (aesthetic veneering, framework, retention screw, implant, and bone tissue) were similar for both groups. The highest stress values were observed between the first and second threads of the retention screw. Considering the bone tissue, the highest stress values were exhibited in the peri-implant cortical bone. The unilateral angular misfit of 100 Km did not influence the stress distribution on the implant-supported prosthesis under static loading.en
dc.description.affiliationUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, Bauru Engn Sch, Dept Mech Engn, BR-16015050 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Bauru Engn Sch, Dept Mech Engn, BR-16015050 São Paulo, Brazil
dc.format.extent1683-1687
dc.identifierhttp://dx.doi.org/10.1097/SCS.0b013e3181f3c64b
dc.identifier.citationJournal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 21, n. 6, p. 1683-1687, 2010.
dc.identifier.doi10.1097/SCS.0b013e3181f3c64b
dc.identifier.issn1049-2275
dc.identifier.lattes4438747643373395
dc.identifier.lattes3383392287039820
dc.identifier.urihttp://hdl.handle.net/11449/15194
dc.identifier.wosWOS:000284829800007
dc.language.isoeng
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofJournal of Craniofacial Surgery
dc.relation.ispartofjcr0.772
dc.relation.ispartofsjr0,448
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectProsthesisen
dc.subjectdental implantsen
dc.subjectmisfiten
dc.subjectsuperstructure materialsen
dc.subjectfinite element analysisen
dc.titlePassivity Versus Unilateral Angular Misfit: Evaluation of Stress Distribution on Implant-Supported Single Crowns: Three-Dimensional Finite Element Analysisen
dc.typeArtigopt
dcterms.licensehttp://edmgr.ovid.com/spine/accounts/copyrightTransfer.pdf
dcterms.rightsHolderLippincott Williams & Wilkins
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes8934648262859482
unesp.author.orcid0000-0002-8903-0737[2]
unesp.author.orcid0000-0002-6510-3727[4]
unesp.author.orcid0000-0002-6391-9917[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Baurupt
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentEngenharia Mecânica - FEBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: