Publicação: Performance of light-emitting diode device in detecting occlusal caries in the primary molars
dc.contributor.author | Diniz, Michele B. | |
dc.contributor.author | Campos, Priscila H. | |
dc.contributor.author | Wilde, Sabrina | |
dc.contributor.author | Cordeiro, Rita de Cassia L. [UNESP] | |
dc.contributor.author | Zandona, Andrea G. F. | |
dc.contributor.institution | Cruzeiro do Sul Univ | |
dc.contributor.institution | Rio Grande do Sul Fed Univ | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Tufts Univ | |
dc.date.accessioned | 2019-10-04T12:39:37Z | |
dc.date.available | 2019-10-04T12:39:37Z | |
dc.date.issued | 2019-08-01 | |
dc.description.abstract | This in vitro study aimed to compare the performance of a light-emitting diode (LED) device (Midwest Caries I.D.: MID), International Caries Detection and Assessment System (ICDAS) visual criteria, and fluorescence-based devices (DIAGNOdent: LF; DIAGNOdent pen: LFpen; and Quantitative Light-induced Fluorescence: QLF) in detecting occlusal caries in the primary molars. Eighty-eight primary molars with sound occlusal surfaces or carious lesions at different stages were assessed twice, with a 1-week interval in between, by one examiner using all three methods. Subsequently, the teeth were sectioned and lesion depth was verified using stereomicroscopy as a gold standard. Sensitivity, specificity, and accuracy were calculated at D-1 (all carious lesions-enamel and dentin) and D-3 (dentin lesions) thresholds. Correlation with histological analysis was evaluated using Spearman's rank correlation coefficients (rho). Weighted Kappa and intraclass-correlation (ICC) coefficients were calculated to assess intra-examiner reproducibility. At D-1 threshold, ICDAS and LFpen showed higher sensitivity than the other methods, whereas ICDAS, LF, and QLF showed higher specificity (p<0.05), and MID showed lower accuracy. At D-3 threshold, ICDAS, LFpen, and QLF showed higher sensitivity than MID, whereas ICDAS, LF, and MID showed higher specificity (p<0.05). All methods, except MID, showed statistically similar accuracy values (p<0.05). Correlations with histopathological analysis varied from 0.15 (MID) to 0.57 (ICDAS). Intra-examiner reproducibility varied from 0.30 (MID) to 0.92 (ICDAS, LF, and QLF). The MID device exhibited a poor performance in detecting occlusal carious lesions in the primary molars, and ICDAS visual criteria exhibited greater accuracy than LF, LFpen, and QLF devices. | en |
dc.description.affiliation | Cruzeiro do Sul Univ, Postgrad Program Dent, Rua Galvao Bueno 868, BR-0150600 Sao Paulo, SP, Brazil | |
dc.description.affiliation | Rio Grande do Sul Fed Univ, Dept Pediat Dent, Rua Ramiro Barcelos 2492, BR-90035004 Porto Alegre, RS, Brazil | |
dc.description.affiliation | Sao Paulo State Univ, Araraquara Sch Dent, Dept Pediat Dent, Rua Humaita 1680, BR-14801903 Araraquara, SP, Brazil | |
dc.description.affiliation | Tufts Univ, Sch Dent Med, Dept Comprehens Care, 1 Kneeland St, Boston, MA 02111 USA | |
dc.description.affiliationUnesp | Sao Paulo State Univ, Araraquara Sch Dent, Dept Pediat Dent, Rua Humaita 1680, BR-14801903 Araraquara, SP, Brazil | |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.format.extent | 1235-1241 | |
dc.identifier | http://dx.doi.org/10.1007/s10103-019-02717-4 | |
dc.identifier.citation | Lasers In Medical Science. London: Springer London Ltd, v. 34, n. 6, p. 1235-1241, 2019. | |
dc.identifier.doi | 10.1007/s10103-019-02717-4 | |
dc.identifier.issn | 0268-8921 | |
dc.identifier.uri | http://hdl.handle.net/11449/185905 | |
dc.identifier.wos | WOS:000475644500021 | |
dc.language.iso | eng | |
dc.publisher | Springer | |
dc.relation.ispartof | Lasers In Medical Science | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | Caries detection | |
dc.subject | Primary teeth | |
dc.subject | Occlusal surfaces | |
dc.subject | Fluorescence | |
dc.title | Performance of light-emitting diode device in detecting occlusal caries in the primary molars | en |
dc.type | Artigo | |
dcterms.license | http://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0 | |
dcterms.rightsHolder | Springer | |
dspace.entity.type | Publication | |
relation.isOrgUnitOfPublication | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
relation.isOrgUnitOfPublication.latestForDiscovery | ca4c0298-cd82-48ee-a9c8-c97704bac2b0 | |
unesp.author.orcid | 0000-0002-0693-2162[1] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Clínica Infantil - FOAR | pt |