Publicação: Effect of ultrasonic instrumentation on the bond strength of crowns cemented with zinc phosphate cement to natural teeth. An in vitro study
dc.contributor.author | de Melo Filho, Antonio Braulino [UNESP] | |
dc.contributor.author | Mori, Matsuyoshi | |
dc.contributor.author | Jardini, Maria Aparecida Neves [UNESP] | |
dc.contributor.author | Landim, Karine Tenório [UNESP] | |
dc.contributor.author | Solis, Ana Cristina de Oliveira | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.contributor.institution | Vale do Paraíba University | |
dc.date.accessioned | 2014-05-27T11:23:44Z | |
dc.date.available | 2014-05-27T11:23:44Z | |
dc.date.issued | 2008-12-01 | |
dc.description.abstract | Several studies have reported the benefits of sonic and/or ultrasonic instrumentation for root debridement, with most of them focusing on changes in periodontal clinical parameters. The present study investigated possible alterations in the tensile bond strength of crowns cemented with zinc phosphate cement to natural teeth after ultrasonic instrumentation. Forty recently extracted intact human third molars were selected, cleaned and stored in physiologic serum at 4°C. They received standard preparations, at a 16° convergence angle, and AgPd alloy crowns. The crowns were cemented with zinc phosphate cement and then divided into four groups of 10 teeth each. Each group was then subdivided into two subgroups, with one of the subgroups being submitted to 5,000 thermal cycles ranging from 55 ± 2 to 5 ± 2°C, while the other was not. Each group was submitted to ultrasonic instrumentation for different periods of time: group 1 - 0 min (control), group 2 - 5 min, group 3 - 10 min, and group 4 - 15 min. Tensile bond strength tests were performed with an Instron testing machine (model 4310). Statistical analysis was performed using ANOVA and Tukey's test at the 5% level of significance. A significant reduction in the tensile bond strength of crowns cemented with zinc phosphate and submitted to thermal cycles was observed at 15 min (196.75 N versus 0 min = 452.01 N, 5 min = 444.23 N and 10 min = 470.85 N). Thermal cycling and ultrasonic instrumentation for 15 min caused a significant reduction in tensile bond strength (p < .05). | en |
dc.description.affiliation | Department of Restorative Dentistry School of Dentistry of São José dos Campos São Paulo State University (UNESP), São José dos Campos, SP | |
dc.description.affiliation | Department of Prosthodontics School of Dentistry University of São Paulo, São Paulo, SP | |
dc.description.affiliation | Department of Periodontics School of Dentistry of São Jose dos Campos São Paulo Statte University (UNESP), São José dos Campos, SP | |
dc.description.affiliation | Department of Periodontics School of Dentistry Vale do Paraíba University, São José dos Campos, SP | |
dc.description.affiliation | , Av. Adhemar de Barros 283/701, São José dos Campos, SP 12245-010 | |
dc.description.affiliationUnesp | Department of Restorative Dentistry School of Dentistry of São José dos Campos São Paulo State University (UNESP), São José dos Campos, SP | |
dc.description.affiliationUnesp | Department of Periodontics School of Dentistry of São Jose dos Campos São Paulo Statte University (UNESP), São José dos Campos, SP | |
dc.format.extent | 270-274 | |
dc.identifier | http://dx.doi.org/10.1590/S1806-83242008000300014 | |
dc.identifier.citation | Brazilian Oral Research, v. 22, n. 3, p. 270-274, 2008. | |
dc.identifier.doi | 10.1590/S1806-83242008000300014 | |
dc.identifier.file | 2-s2.0-60649120799.pdf | |
dc.identifier.issn | 1806-8324 | |
dc.identifier.issn | 1807-3107 | |
dc.identifier.lattes | 5733639342016958 | |
dc.identifier.scielo | S1806-83242008000300014 | |
dc.identifier.scopus | 2-s2.0-60649120799 | |
dc.identifier.uri | http://hdl.handle.net/11449/70720 | |
dc.language.iso | eng | |
dc.relation.ispartof | Brazilian Oral Research | |
dc.relation.ispartofjcr | 1.223 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Scopus | |
dc.subject | Tensile strength | |
dc.subject | Tooth crown | |
dc.subject | Ultrasonic therapy | |
dc.subject | Zinc phosphate cement | |
dc.subject | zinc phosphate | |
dc.subject | analysis of variance | |
dc.subject | cementation | |
dc.subject | chemistry | |
dc.subject | debridement | |
dc.subject | echography | |
dc.subject | endodontics | |
dc.subject | human | |
dc.subject | instrumentation | |
dc.subject | materials testing | |
dc.subject | methodology | |
dc.subject | surface property | |
dc.subject | tensile strength | |
dc.subject | time | |
dc.subject | tooth crown | |
dc.subject | ultrasound therapy | |
dc.subject | Analysis of Variance | |
dc.subject | Cementation | |
dc.subject | Debridement | |
dc.subject | Humans | |
dc.subject | Materials Testing | |
dc.subject | Root Canal Therapy | |
dc.subject | Surface Properties | |
dc.subject | Tensile Strength | |
dc.subject | Time Factors | |
dc.subject | Tooth Crown | |
dc.subject | Ultrasonic Therapy | |
dc.subject | Zinc Phosphate Cement | |
dc.title | Effect of ultrasonic instrumentation on the bond strength of crowns cemented with zinc phosphate cement to natural teeth. An in vitro study | en |
dc.type | Artigo | |
dcterms.license | http://www.scielo.br/revistas/bor/paboutj.htm | |
dspace.entity.type | Publication | |
unesp.author.lattes | 5733639342016958 | |
unesp.author.lattes | 3462975841163856[1] | |
unesp.author.orcid | 0000-0002-7794-2851[1] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Odontologia Restauradora - ICT | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- 2-s2.0-60649120799.pdf
- Tamanho:
- 111.83 KB
- Formato:
- Adobe Portable Document Format